The AirTAC GAC F.R.L. Unit GAC300C15LWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC300C15LWT combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port serves a 1300 g assembly that uses a metal bowl and a 5 um element to trap fine particles before they reach precision valves. Because the lubricator sits last in the airflow path, oil mist is introduced downstream of the regulator seat, preventing fouling of the pressure-control mechanism.
This lower-pressure type regulates between 0.15-0.4 MPa (20-58 psi), making it suitable for low-force actuator networks rather than main factory headers. A circular gauge is fitted, reading MPa/psi for the default NPT thread, so operators can verify the set pressure directly. Condensate is managed by a semi-auto and manual drain pair within a 60 cc bowl, requiring active intervention during pressure drops or scheduled checks.
| Model | Airtac GAC F.R.L. Unit GAC300C15LWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air to sensitive test fixtures and glassware handling actuators that require a stable 0.4 MPa maximum supply.
Conditions air for delicate tension-control cylinders where a 5 um element prevents clogging in fine yarn guiding valves.
Supplies regulated, lubricated air to low-force capping heads, ensuring consistent torque without stressing plastic bottle threads.
Choose this 1300 g unit when a 1/2in port line requires fine 5 um filtration and a low-pressure ceiling, stepping up from the GAC200 which offers a 1750 L/min plotted flow envelope at 0.7 MPa inlet compared to this body's 3000 L/min curve. The metal bowl suits harsher industrial environments where PC or nylon might not be permitted, though buyers must confirm chemical compatibility. If the downstream circuit must remain oil-free, omit the lubricator and choose a filter-regulator instead. Replacement spares share the same body-port suffix: GAF300-15, GAR300-15 and GAL300-15. Note that the 0.4 MPa upper limit is 44% of the Standard type's 0.9 MPa ceiling, so verify your actuators never require more force than this lower range permits.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 1/2in port, a 5 um element, a metal bowl, and a semi-auto+manual drain. The unit weighs 1300 g, has a 60 cc drain bowl capacity, a 98 cc oil bowl capacity, and functions between -5 to 70 C using ISO VG 32 lubricant.
The 5 um W-grade element captures far finer particles than the standard 40 um filter, protecting precision instruments but requiring more frequent replacement. The metal bowl provides durability in demanding settings, and the unit uses a semi-auto and manual drain setup, meaning condensate is ejected automatically on pressure drops but can also be purged manually during routine checks.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.