The AirTAC GAC F.R.L. Unit GAC300C15LWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC300C15LWTK combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a 5 um element to trap fine particles before they reach sensitive valves. Because the lubricator sits last in the sequence, oil mist enters downstream of the regulator seat, preventing fouling. The metal bowl equips this assembly for rugged plant environments.
Operating in the lower pressure band of 0.15-0.4 MPa (20-58 psi), it suits circuits requiring gentle actuation rather than full-line force. The assembly includes a reverse-flow (reflux) valve, shown as a separate pneumatic symbol in the catalogue. A circular gauge reading MPa/psi is fitted for the default NPT thread, allowing operators to monitor the set pressure directly. Weighing 1300 g, the unit carries a 60 cc condensate bowl and a 98 cc oil reservoir.
| Model | Airtac GAC F.R.L. Unit GAC300C15LWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air to sensitive lab dosing pumps and glass-handling actuators that require a stable 0.4 MPa maximum output.
Conditions air for delicate film-handling grippers where the 5 um element protects narrow nozzles from clogging.
Lubricates and regulates air for weaving loom cylinders that demand gentle, consistent pressure to avoid yarn breakage.
Choose this configuration when a 1/2in line needs low-pressure regulation capped at 0.4 MPa, combined with fine 5 um filtration. The metal bowl offers durability where impacts might occur, and the semi-auto plus manual drain pair gives operators dual control over condensate evacuation. If the downstream process requires absolutely oil-free air, omit the lubricator and select a standalone filter-regulator instead. For maintenance, the individual elements are available as GAF300-15, GAR300-15 and GAL300-15.
Stepping up to the GAC400 body increases the condensate capacity to 100 cc and the plotted flow envelope to 6000 L/min at 0.7 MPa inlet, compared to the 3000 L/min envelope of this GAC300. However, choosing the L type restricts the top setting to 44% of the Standard type's 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, features a 5 um element, and includes a 60 cc drain bowl alongside a 98 cc oil bowl. The assembly weighs 1300 g and uses ISO VG 32 lubricant.
The K indicates that a reverse-flow (reflux) valve is fitted. The catalogue displays this as a distinct pneumatic symbol with specific details provided on its own dedicated page.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.