The AirTAC GAC F.R.L. Unit GAC300C15SNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a 1300 g mass, placing it firmly in the GAC300 size class, and the standard type regulates pressure from 0.15-0.9 MPa (20-130 psi). A 40 um element captures solid particles, while the metal bowl equips the unit for rugged plant environments.
Air passes through the filter, regulator and lubricator in that exact sequence, adding oil mist downstream of the regulator seat to prevent fouling. Because the N code follows the port, no gauge is supplied; the 1/8in gauge connection allows a panel instrument to be added later if visual pressure reading is needed. The reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue, and the 60 cc condensate bowl sets the routine maintenance interval. Order code GAC300C15SNTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C15SNTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds pneumatic impact wrenches and actuators on a 1/2in line, supplying steady pressure and oil mist for high-cycle moving parts.
Conditions air for folding cylinders and sealing jaws, relying on the 40 um element to protect precision valves from particulate fouling.
Prepares compressed air for diverters and pushers on 1/2in ported routing networks, using the metal bowl to withstand shop-floor impacts.
Choose this metal-bowl GAC300 unit for 1/2in ported machinery requiring a 0.15-0.9 MPa (20-130 psi) operating range. The semi-auto and manual drain pair clears accumulated moisture on every pressure drop or on operator demand. If your downstream line must remain strictly oil-free, omit the lubricator and select a dedicated filter-regulator instead. For maintenance, the assembly accepts individual GAF300-15, GAR300-15 and GAL300-15 replacement units. Stepping up to the GAC400 body roughly doubles the plotted flow envelope from 3000 to 6000 L/min at 0.7 MPa inlet, but the GAC300 offers a lighter 1300 g footprint. The 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin above the 1.0 MPa maximum, though it is never permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, uses a 40 um element, and pairs a 60 cc drain bowl with a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
The N after the port code indicates no gauge is supplied from the factory. The unit features a 1/8in gauge connection, allowing operators to install a separate NPT-threaded instrument reading MPa/psi to match their specific monitoring preferences.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.