The AirTAC GAC F.R.L. Unit GAC300C15SNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, pressure-set and oil-misted air, the AirTAC GAC300C15SNWT is a three-unit F.R.L. combination pairing a filter, regulator and lubricator on a single L-shape bracket. This 1/2in port variant uses a 5 um element to trap fine particles for sensitive pneumatics, operating within a 0.15-0.9 MPa (20-130 psi) standard pressure range. The metal bowl equips it for rugged plant environments.
Air flows through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Weighing 1300 g, the assembly carries a 60 cc condensate bowl and a 98 cc oil reservoir. No gauge is supplied, but a 1/8in gauge connection allows operators to add instrumentation for verifying the 0.15-0.9 MPa setpoint. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C15SNWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, lubricated air at a stable pressure to pneumatic tool-change cylinders, where the 5 um element protects tight-tolerance spools from grit.
Conditions supply air for high-cycle sealing actuators, ensuring the lubricator adds a consistent oil mist to prolong moving-seal life.
Prepares plant air for multi-station spinning equipment, using the metal bowl to withstand the humid, lint-heavy atmosphere of a fiber mill.
This model uses a metal bowl and a 5 um element, trading the standard 40 um particle capture for finer protection suited to precision valves, at the cost of more frequent element service. The semi-auto and manual drain pair is fitted, dumping condensate on pressure drops or on demand. Because no gauge is included, you must add one to the 1/8in port to read the set pressure; the default NPT thread dictates an MPa/psi scale. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead. Spares follow the GAF300-15, GAR300-15 and GAL300-15 part numbers. Stepping down to the GAC200 body shrinks the plotted flow envelope from 3000 to 1750 L/min at 0.7 MPa inlet, while the 1.5 MPa proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum operating limit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 1300 g, holds 60 cc of condensate and 98 cc of oil, and requires ISO VG 32 lubricant.
The N in the part number means no gauge is shipped, but the body features a 1/8in connection to mount one later. The W code specifies a 5 um filter element, which catches far finer particulates than the default 40 um grade to protect sensitive instruments, though it requires more frequent replacement.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.