The AirTAC GAC F.R.L. Unit GAC300C15ST is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatic systems, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a standard 0.15-0.9 MPa (20-130 psi) pressure range, while the 40 um element captures solid grain before it reaches downstream valves.
The metal bowl equips this specific assembly for harsher industrial settings where polycarbonate might risk impact damage. Air passes through the filter first, then the regulator sets the working pressure, and the lubricator adds oil mist last so the regulator seat stays clean. A circular gauge is fitted, reading MPa/psi for the default NPT thread, allowing operators to monitor the set pressure directly at the unit. Order code GAC300C15ST has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C15ST |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds a central distribution manifold for a multi-lane packaging machine, ensuring consistent pressure and lubrication for high-speed pneumatic actuators.
Conditions the air feeding an automatic tool changer system, where the 40 um element protects sensitive tool-release cylinders from particulate ingress.
Supplies clean, regulated and lubricated air to a series of pneumatic pop-up diverters on a parcel sorting conveyor, reducing wear on moving seals.
Choose this GAC300 body for duties requiring a 1/2in port, sitting between the lighter GAC200 and the larger GAC400. The catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, offering a sizing envelope that is double the 1750 L/min of the smaller GAC200. If your line must remain strictly oil-free, omit the lubricator and choose a filter-regulator instead, as this unit actively adds an oil mist downstream.
The three constituent parts are separately orderable as GAF300-15, GAR300-15 and GAL300-15, meaning a clogged element does not require replacing the whole assembly. Because the maximum supply is 1.0 MPa and the Standard type regulates to 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting, so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type F.R.L. unit has a 1/2in port and regulates from 0.15-0.9 MPa (20-130 psi). The maximum pressure is 1.0 MPa (145 psi) with a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, and features a 60 cc drain bowl with a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
The C in the code specifies a metal bowl, chosen for environments where polycarbonate might suffer impact. Because the drain position is blank, it ships with both a semi-auto drain (which dumps condensate on each pressure drop) and a manual drain for on-demand emptying, giving operators dual control over the 60 cc bowl.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.