The AirTAC GAC F.R.L. Unit GAC300N15ASNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic machinery, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 1/2in port, a 40 um element and a standard pressure range of 0.15-0.9 MPa (20-130 psi). The nylon bowl equips this assembly for environments where polycarbonate might be unsuitable, while the automatic drain clears condensate without operator intervention.
Air flows through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Because the N follows the port in the code, no pressure gauge is supplied; operators can add one via the 1/8in gauge connection. Weighing 1300 g, the assembly incorporates a 60 cc condensate bowl and a 98 cc oil reservoir. Order code GAC300N15ASNT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N15ASNT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds multiple pneumatic pick-and-place actuators on a carousel, providing steady 0.6 MPa pressure and oil mist to keep sliding seals lubricated during continuous high-speed cycling.
Conditions air for pneumatic forming and sealing jaws, relying on the automatic drain to expel condensate during long production runs without halting the conveyor.
Supplies clean, regulated air to pop-up pneumatic cylinders that sort packages, ensuring consistent actuation speed and protecting internal valves from particulate ingress.
Choose this GAC300 size class for medium flow duties, noting its catalogue flow curve is plotted to 3000 L/min at 0.7 MPa inlet, whereas the GAC400 is plotted to 6000 L/min. The 40 um element suits general plant air, but a 5 um W variant is available for finer filtration. Since this model has no gauge, the set pressure cannot be read unless one is added to the 1/8in port. If the downstream line must remain oil-free, omit the lubricator and choose a separate filter-regulator instead. Replacement spares share the 300-15 suffix: GAF300-15, GAR300-15 and GAL300-15. The 1.0 MPa maximum supply leaves only about 0.1 MPa of headroom above the 0.9 MPa standard ceiling, so plan a supply near 1.0 MPa if you truly need maximum outlet pressure.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It functions from -5 to 70 C, uses a 40 um element, weighs 1300 g, has a 60 cc drain bowl and a 98 cc oil bowl, and requires ISO VG 32 lubricant.
The N after the port code indicates no gauge is supplied. The body features a 1/8in gauge connection, allowing operators to install a separate circular gauge reading MPa/psi for the default NPT thread if visual pressure monitoring is required.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.