The AirTAC GAC F.R.L. Unit GAC300N15ASNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in ported body operates at 0.15-0.9 MPa (20-130 psi) and utilizes a 5 um element to capture fine particulates before they reach sensitive valves.
Because the nylon bowl assembly includes an automatic drain, condensate is purged continuously without an operator. No pressure gauge is supplied, but the housing retains a 1/8in gauge connection should you need to add instrumentation to verify the 0.15-0.9 MPa downstream setting. Order code GAC300N15ASNWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N15ASNWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds loom and spinner actuator lines where the 5 um element protects delicate air-jet nozzles from lint and dust.
Conditions air for high-speed sorting cylinders, relying on the automatic drain to handle wet compressor output continuously.
Supplies stable 0.15-0.9 MPa pressure to analyzer actuators, with the nylon bowl offering a lightweight, non-corrosive reservoir.
Choose this 1300 g assembly for 1/2in lines requiring unattended condensate management and fine 5 um filtration. The automatic drain clears the 60 cc condensate sump independently, a major advantage over the semi-auto and manual pair found on blank-drain variants. If your downstream process cannot tolerate oil mist, you must omit the lubricator and select a separate filter-regulator instead. For maintenance, the individual elements and bowls are separately orderable as GAF300-15, GAR300-15 and GAL300-15. Stepping up to the GAC400 body increases the plotted flow envelope from 3000 to 6000 L/min at 0.7 MPa inlet, effectively doubling the available air capacity, while the 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum operating limit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It features a 1/2in port, 5 um element, automatic drain, 60 cc drain bowl, 98 cc oil bowl, and weighs 1300 g. The operating temperature is -5 to 70 C using ISO VG 32 lubricant.
The N in the ordering code indicates no gauge is supplied from the factory. The regulator body retains a 1/8in gauge connection, allowing operators to install a compatible MPa/psi pressure indicator separately to monitor the downstream setting.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.