The AirTAC GAC F.R.L. Unit GAC300N15LTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAC300N15LTK is a three-in-one air preparation assembly: a filter, a regulator and a lubricator mounted together on a single L-shaped bracket with quick clamps. The 1/2in port and 1300 g mass place it in the mid-size GAC300 class, suited to feeding a small machine header or a few actuators from one conditioned supply point. Air moves through the filter first, then the regulator, and the oil mist is added last so it never reaches the regulator seat.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), and a circular gauge with an MPa/psi scale is fitted to show the set point. The nylon bowls hold 60 cc of condensate and 98 cc of oil, and the 40 um element handles standard shop air. The reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue. Maximum supply is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and the unit is rated for -5 to 70 C without freezing. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N15LTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feed a workbench of pneumatic screwdrivers or nutrunners that need a stable 0.3 MPa supply, with the regulator holding the set point against small demand swings.
Condition air for a benchtop cylinder test rig or a leak-test fixture where a gentle, repeatable pressure under 0.4 MPa protects sensitive components.
Supply one semi-automatic assembly station with filtered, regulated and lubricated air for its clamping cylinder and a small parts-eject actuator.
Choose the GAC300N15LTK when a 1/2in port and a 0.15-0.4 MPa (20-58 psi) regulated output match your circuit, and when the line must stay oil-free downstream, remember this is a lubricating unit - pick a filter-regulator instead. The nylon bowls suit environments where a clear view of the contents is less important than impact resistance, and the semi-auto plus manual drain pair clears condensate on pressure drops or on demand. The 40 um element is the standard grade; the 5 um option is available as a W code if finer filtration is needed. The NPT thread carries the default MPa/psi gauge scale, and the K code adds the reverse-flow valve. Spare units for this body and port are the GAF300-15 filter, GAR300-15 regulator and GAL300-15 lubricator, each orderable separately.
The lower-pressure ceiling of 0.4 MPa is about 44% of what the standard 0.9 MPa type offers, so confirm the downstream demand never exceeds this before committing.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
The GAC300N15LTK is a GAC300-series F.R.L. combination with a 1/2in port. The lower-pressure regulator range is 0.15-0.4 MPa (20-58 psi). Maximum supply pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 60 cc and the oil bowl 98 cc. Recommended lubricant is ISO VG 32. The unit weighs 1300 g.
The K code means a reverse-flow (reflux) valve is fitted to the GAC300N15LTK. The catalogue shows this valve as a separate pneumatic symbol in the circuit, with its own detail page. It is an ordering difference to note; the valve is included on this model.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.