The AirTAC GAC F.R.L. Unit GAC300N15STK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this GAC300N15STK assembly combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port serves standard duties at 0.15-0.9 MPa (20-130 psi) with a 40 um element. A nylon bowl is fitted, and the unit includes a reverse-flow (reflux) valve shown as a separate pneumatic symbol in the catalogue.
Air passes through the filter first, then the regulator, before oil mist is added downstream by the lubricator so the regulator seat stays clean. The 60 cc condensate bowl and 98 cc oil capacity dictate the maintenance rhythm for this 1300 g unit. A circular gauge is fitted, reading MPa/psi for the default NPT thread.
| Model | Airtac GAC F.R.L. Unit GAC300N15STK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds pneumatic screwdrivers and nutrunners along a 1/2in automated assembly line, providing the 40 um filtered air and oil mist required to keep air motors running smoothly.
Conditions air for packaging machinery where the 0.15-0.9 MPa operating range is ideal for driving the cylinders that fold and seal corrugated boxes.
Supplies stable pressure to pop-up pneumatic diverters on conveyor sorting systems, ensuring consistent actuation speeds across multiple distribution lanes.
Choose this 1/2in nylon-bowl model for typical factory air lines where operators can manually drain condensate on demand using the fitted semi-auto and manual drain pair. If your line must stay completely oil-free, omit the lubricator and choose a filter-regulator instead. The three units are separately orderable as GAF300-15, GAR300-15 and GAL300-15, so a damaged bowl or clogged element never requires replacing the whole assembly. Stepping up to the GAC400 roughly doubles the flow envelope from 3000 to 6000 L/min at 0.7 MPa inlet, but this lighter 1300 g body is easier to panel mount. Because the maximum supply is 1.0 MPa and the standard type regulates to 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting, so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 1300 g, has a 60 cc drain bowl and a 98 cc oil bowl, and uses ISO VG 32 lubricant.
The K signifies that a reverse-flow (reflux) valve is fitted to this model. The catalogue depicts this as a distinct pneumatic symbol with specific details provided on its own page.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.