The AirTAC GAC F.R.L. Unit GAC300N15SWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic machinery, this AirTAC GAC300N15SWTK combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port serves the standard 0.15-0.9 MPa (20-130 psi) pressure range, while the 5 um element captures far finer particles than the default 40 um grade, trading element service frequency for precision valve protection.
Air passes through the filter first, then the regulator, so the lubricator's oil mist is introduced strictly downstream of the regulator seat to prevent fouling. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
| Model | Airtac GAC F.R.L. Unit GAC300N15SWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Supplies finely filtered, oil-misted air to precision machining center actuators where 5 um particulate control protects sensitive tooling changers.
Conditions air for high-speed bottling line diverter valves, ensuring the standard 0.15-0.9 MPa operating band holds steady during rapid cycling.
Prepares supply for multi-actuator robotic assembly stations, using the 98 cc oil bowl to maintain consistent downstream lubrication.
Choose this 1/2in GAC300 unit when a machine demands high-filtration precision, as the 5 um W element catches particulates that would pass a standard 40 um filter. The nylon bowl offers a distinct build alternative to the standard PC or metal options, though buyers must confirm material compatibility with aggressive surroundings. The semi-auto and manual drain pair clears condensate on pressure drops or on demand, and the fitted gauge lets operators verify the 0.15-0.9 MPa (20-130 psi) setting at a glance. If the downstream line must remain completely oil-free, omit the lubricator and select a dedicated filter-regulator instead. For maintenance, the individual GAF300-15, GAR300-15 and GAL300-15 components are separately orderable. Stepping up to the GAC400 body roughly doubles the flow envelope from 3000 to 6000 L/min at 0.7 MPa inlet, but the 1.5 MPa (215 psi) proof pressure against the 1.0 MPa (145 psi) maximum provides a 1.5x burst-test margin here.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C, features a 60 cc drain bowl and a 98 cc oil bowl, weighs 1300 g, and uses ISO VG 32 lubricant.
The K indicates a reverse-flow (reflux) valve is fitted, which the catalogue details on its own page. The 5 um W element provides finer filtration than the standard 40 um grade, trapping smaller particles for precision pneumatics at the cost of more frequent element service.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.