The AirTAC GAC F.R.L. Unit GAC40015ALTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for medium-scale pneumatics, the GAC40015ALTK integrates a filter, regulator and lubricator on a single L-shape bracket. This assembly features a 1/2in port, a 40 um element and a lower pressure regulating range of 0.15-0.4 MPa (20-58 psi). The automatic drain clears condensate from the 100 cc bowl without operator intervention, while a fitted circular gauge reads MPa/psi for the default NPT thread.
Air passes through the filter first, then the regulator, before oil mist is introduced downstream by the lubricator so the regulator seat stays clean. Weighing 2390 g, this unit needs a firm panel or frame mount rather than tubing support. The reverse-flow valve is fitted, shown as a separate pneumatic symbol in the catalogue. If your downstream line requires clean air without oil, omit the lubricator and choose a filter-regulator instead.
| Model | Airtac GAC F.R.L. Unit GAC40015ALTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate bagging and sealing actuators where air pressure must stay under 0.4 MPa to prevent crushing product.
Conditions supply air for looms and spinning frames, adding necessary oil mist for high-speed moving parts.
Regulates stable low-pressure air for sensitive benchtop dispensers and test fixtures requiring precise force.
This assembly suits low-pressure circuits up to 0.4 MPa, making it the wrong choice if the machine might ever need standard 0.9 MPa output. The PC bowl handles standard -5 to 70 C environments, but you should confirm compatibility for aggressive surroundings. The fitted gauge lets operators verify the set pressure directly, and the 40 um element balances particle trapping with a standard service interval. For maintenance, the three units are separately orderable as GAF400-15, GAR400-15 and GAL400-15. Stepping down to the GAC300 halves the plotted flow envelope to 3000 L/min at 0.7 MPa inlet, whereas this body reaches 6000 L/min. Choosing the L type means the 0.4 MPa ceiling is just 44% of the standard 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type regulates 0.15-0.4 MPa (20-58 psi) and carries a max pressure of 1.0 MPa (145 psi) with a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 2390 g, and uses a 100 cc drain bowl with a 185 cc oil bowl. The recommended lubricant is ISO VG 32.
The K signifies that a reverse-flow (reflux) valve is attached. The catalogue displays this as a distinct pneumatic symbol on its own page, and no functional details are provided in the main specifications.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.