The AirTAC GAC F.R.L. Unit GAC40015ALWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, lubricated air at a strictly limited downstream pressure, the GAC40015ALWT pre-assembles a filter, regulator and lubricator on a single L-shape bracket. This 1/2in ported assembly uses a 5 um element to capture fine particles before the air reaches the regulator, which sets an outlet pressure of 0.15-0.4 MPa (20-58 psi). The build sequence places the lubricator last, adding oil mist downstream of the regulator seat so it never fouls the pressure-control mechanism.
Weighing 2390 g, this body carries a 100 cc condensate bowl paired with a 185 cc oil reservoir. The automatic drain clears accumulated water without an operator, which is decisive for wet lines or unattended machinery. A circular gauge is fitted, reading MPa/psi for the default NPT thread, so technicians can verify the low-pressure setting at a glance.
| Model | Airtac GAC F.R.L. Unit GAC40015ALWT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive pneumatic grippers and small-bore cylinders on electronics assembly lines where operating pressure must stay below 0.4 MPa to prevent component damage.
Conditions air for packaging machinery that relies on delicate vacuum cups and low-force clamps, using the 5 um element to protect tiny nozzle clearances from clogging.
Supplies clean, lubricated air to benchtop fluid dispensing robots and test fixtures, ensuring stable low-pressure output without manual condensate draining.
Choose this 1/2in unit when a machine requires highly filtered, low-pressure air, as the 5 um element traps far finer particulates than the 40 um standard, benefiting precision valves. If the application might ever demand more than 0.4 MPa, the L type is the wrong part and a standard S type is required instead. Because oil mist is added downstream, select a separate filter-regulator if the line must remain oil-free. Should a component fail, the three units are separately orderable as GAF400-15, GAR400-15 and GAL400-15.
The catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, which is 86% of the GAC500's 7000 L/min envelope. Keep in mind that 0.4 MPa is about 44% of the Standard type's 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It has a 1/2in port, a 5 um element, a 100 cc drain bowl, a 185 cc oil bowl, and weighs 2390 g. The temperature range is -5 to 70 C and the recommended lubricant is ISO VG 32.
The A in the code signifies an automatic drain that expels condensate without operator intervention, ideal for wet environments. The W denotes a 5 um filter element, which catches much finer particulates than the standard 40 um grade, making it suitable for protecting sensitive instrumentation.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.