The AirTAC GAC F.R.L. Unit GAC40015ALWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainautomatic
  • Pressure gaugeCircular, psi / bar
  • Weight2390 g
$135.40 $142.90Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GAC400-15 bowl, type and element option on one page All GAC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac GAC F.R.L. Unit GAC40015ALWTK

Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC40015ALWTK F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/2in port pairs with a 5 um element to trap fine particles before they reach precision valves. Because the lubricator sits last in the sequence, the oil mist is added downstream of the regulator seat, preventing fouling during pressure control.

Designed for low-pressure duties, the regulator operates within 0.15-0.4 MPa (20-58 psi). The unit carries an automatic drain that empties the 100 cc condensate bowl without operator intervention, while a fitted circular gauge reads MPa/psi for the default NPT thread. A reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page.

Airtac GAC F.R.L. Unit GAC40015ALWTK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC40015ALWTK
SeriesGAC400 F.R.L. combination
Port size1/2" (NPT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight2390 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.

Model Code: Airtac GAC F.R.L. Unit GAC40015ALWTK

GAC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
TNPT thread; gauge scale psi / bar.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC400 · 1/2" · curve to 6000 L/min
One size downGAC300
One size upGAC500 (curve to 7000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC40015ALWTK Is Used

precision_manufacturing

Precision Valve Lines

Feeds low-pressure air to sensitive pilot valves and proportional regulators in semiconductor handling, relying on the 5 um element to prevent seat contamination.

package_2

Light-Clamp Packaging

Supplies a steady 0.4 MPa to delicate gripping jaws on flow-wrapping machines, ensuring film is held without crushing the product.

science

Lab Pneumatic Rigs

Conditions air for low-force test fixtures and analytical instruments, using the automatic drain to handle condensate during long unattended runs.

Is the Airtac GAC F.R.L. Unit GAC40015ALWTK the Right Air-Prep Unit?

Choose this configuration when a 1/2in port and a 0.15-0.4 MPa (20-58 psi) operating ceiling match your downstream actuators. The 5 um element provides finer filtration than the 40 um standard, suiting sensitive instrumentation, though it requires more frequent element replacement. If the machine must remain oil-free, omit the lubricator and select a filter-regulator instead. The automatic drain suits unattended or wet lines, and the PC bowl is rated for the standard -5 to 70 C range. Should a component fail, order the GAF400-15, GAR400-15 and GAL400-15 spares rather than replacing the whole assembly. Keep in mind that 0.4 MPa is 44% of the Standard type's 0.9 MPa ceiling.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 2390 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC40015ALWTK FAQ

This lower-pressure type unit regulates from 0.15-0.4 MPa (20-58 psi). It has a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 100 cc, the oil bowl holds 185 cc, the recommended lubricant is ISO VG 32, and the assembly weighs 2390 g.

The A denotes the automatic drain, clearing condensate without manual intervention. L sets the lower 0.15-0.4 MPa pressure range. W specifies the 5 um fine element, and K indicates a reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC40015ALWTK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GAC40015ALWTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.