The AirTAC GAC F.R.L. Unit GAC40015ALWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC40015ALWTK F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/2in port pairs with a 5 um element to trap fine particles before they reach precision valves. Because the lubricator sits last in the sequence, the oil mist is added downstream of the regulator seat, preventing fouling during pressure control.
Designed for low-pressure duties, the regulator operates within 0.15-0.4 MPa (20-58 psi). The unit carries an automatic drain that empties the 100 cc condensate bowl without operator intervention, while a fitted circular gauge reads MPa/psi for the default NPT thread. A reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page.
| Model | Airtac GAC F.R.L. Unit GAC40015ALWTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air to sensitive pilot valves and proportional regulators in semiconductor handling, relying on the 5 um element to prevent seat contamination.
Supplies a steady 0.4 MPa to delicate gripping jaws on flow-wrapping machines, ensuring film is held without crushing the product.
Conditions air for low-force test fixtures and analytical instruments, using the automatic drain to handle condensate during long unattended runs.
Choose this configuration when a 1/2in port and a 0.15-0.4 MPa (20-58 psi) operating ceiling match your downstream actuators. The 5 um element provides finer filtration than the 40 um standard, suiting sensitive instrumentation, though it requires more frequent element replacement. If the machine must remain oil-free, omit the lubricator and select a filter-regulator instead. The automatic drain suits unattended or wet lines, and the PC bowl is rated for the standard -5 to 70 C range. Should a component fail, order the GAF400-15, GAR400-15 and GAL400-15 spares rather than replacing the whole assembly. Keep in mind that 0.4 MPa is 44% of the Standard type's 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type unit regulates from 0.15-0.4 MPa (20-58 psi). It has a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 100 cc, the oil bowl holds 185 cc, the recommended lubricant is ISO VG 32, and the assembly weighs 2390 g.
The A denotes the automatic drain, clearing condensate without manual intervention. L sets the lower 0.15-0.4 MPa pressure range. W specifies the 5 um fine element, and K indicates a reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.