The AirTAC GAC F.R.L. Unit GAC40015AST is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatics, the AirTAC GAC40015AST is a complete F.R.L. combination built around a 1/2in port. It pairs a 40 um filter, a pressure regulator and a lubricator on a single L-shape bracket, eliminating inter-unit tubing. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Weighing 2390 g, this body size sits firmly in the mid-range class and requires a proper panel or frame mount rather than support from the piping. The automatic drain actively clears the 100 cc condensate bowl without an operator, a crucial feature for wet lines or unattended machinery. Air passes through the filter first, then the regulator, so the oil mist added by the lubricator never fouls the regulator seat.
| Model | Airtac GAC F.R.L. Unit GAC40015AST |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds main air headers for robotic welding cells and stamping presses where a steady 1/2in supply and automatic condensate draining keep heavy actuators cycling without moisture interruptions.
Conditions air for high-speed carton forming and sealing heads, relying on the 40 um element to protect grippers and the lubricator to oil fast-moving pneumatic jaws.
Supplies regulated, lubricated air to heavy-load transfer cylinders and diverters, ensuring consistent push forces across long shift cycles in distribution centers.
Choose this 1/2in PC bowl model when you need automatic condensate evacuation alongside a standard 0.15-0.9 MPa pressure range. The 40 um element suits general plant air, whereas a 5 um variant is better for precision valves. Because the lubricator introduces oil mist downstream, pick a separate filter-regulator if your line must remain strictly oil-free. Should a component fail, the assembly splits into GAF400-15, GAR400-15 and GAL400-15 spares. Stepping down to a GAC300 halves the plotted flow envelope to 3000 L/min at 0.7 MPa inlet, whereas this 400 body reaches 6000 L/min. Furthermore, the 1.5 MPa proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, though this never permits running above the rated limit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This unit operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It features a 1/2in port, a 100 cc drain bowl, a 185 cc oil bowl, a 40 um element, and weighs 2390 g. The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32.
The A in the ordering code denotes an automatic drain fitted to the 100 cc PC bowl. It expels collected condensate without manual intervention, making the unit highly suitable for unattended installations or environments with heavy moisture load.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.