The AirTAC GAC F.R.L. Unit GAC40015LTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatics, this GAC40015LTK assembly integrates a filter, regulator and lubricator on a shared L-shape bracket. It features a 1/2in port, a standard 40 um element and a lower pressure type operating range of 0.15-0.4 MPa (20-58 psi). A circular gauge is fitted, reading MPa/psi for the default NPT thread, while the reverse-flow (reflux) valve is included as a distinct ordering option.
Weighing 2390 g, the unit pairs a 100 cc condensate bowl with a 185 cc oil reservoir to set the maintenance interval. The build order routes air through the filter first, then the regulator, adding oil mist last so the regulator seat stays clean. Condensate is expelled via the fitted semi-auto and manual drain pair.
| Model | Airtac GAC F.R.L. Unit GAC40015LTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure actuator lines on case sealers where a 1/2in supply distributes steady air without over-pressurizing delicate gripper arms.
Conditions air for loom and knitting cylinder pneumatics, adding required oil mist for high-speed moving spindles while capping output at 0.4 MPa.
Prepares supply for analytical instrument actuators, using the 40 um element to protect sensitive valves from pipeline scale.
Choose this 1/2in body for mid-scale duties, stepping down to the GAC300 (plotted to 3000 L/min at 0.7 MPa inlet) or up to the GAC500 (plotted to 7000 L/min). The PC bowl suits general plant air within the shared -5 to 70 C limit. Because this is an L type capped at 0.4 MPa, select a standard S model if the machine might ever need more pressure. Remember that oil mist is added downstream, so choose a filter-regulator if the line must stay oil-free. Spares are GAF400-15, GAR400-15 and GAL400-15. The 0.4 MPa ceiling is 44% of the 0.9 MPa standard type maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It has a 1/2in port, a 100 cc drain bowl, a 185 cc oil bowl, a 40 um element, and weighs 2390 g. The temperature range is -5 to 70 C and the recommended lubricant is ISO VG 32.
The L indicates a lower pressure type limited to 0.15-0.4 MPa (20-58 psi), making it unsuitable for systems requiring higher settings. The K means a reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.