The AirTAC GAC F.R.L. Unit GAC40015LWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for mid-sized pneumatics, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2" port pairs with a 5 um element to trap fine particulates before they reach sensitive valves. Because the lubricator sits downstream of the regulator, oil mist is introduced last, preventing fouling of the regulating seat.
Configured for lower-pressure duties, the unit operates within a 0.15-0.4 MPa (20-58 psi) range. It carries a 100 cc condensate bowl and a 185 cc oil reservoir, requiring 2390 g of mass that demands a firm panel mount rather than tubing support. The NPT thread pairs with a fitted circular gauge reading MPa/psi, while a semi-auto and manual drain pairing handles condensate removal. Order code GAC40015LWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC40015LWT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds 5 um filtered air to sensitive directional control valve banks operating under low-pressure safety limits.
Supplies a steady 0.4 MPa to delicate pneumatic grippers and clamps that handle thin films without crushing the product.
Conditions air for metering pumps and low-pressure actuators where exact pressure regulation and fine filtration are mandatory.
Choose this 1/2" ported assembly when a system needs the 5 um element for precision instrumentation, as the finer mesh demands more frequent element service than the 40 um standard. The lower-pressure type tops out at 0.4 MPa, making it the wrong choice if a machine might ever require higher actuation force. If the downstream line must remain completely oil-free, omit the lubricator and select a dedicated filter-regulator instead. The constituent parts are separately orderable as GAF400-15, GAR400-15 and GAL400-15, meaning a clogged screen does not require replacing the whole assembly. Stepping up to the GAC500 increases the flow envelope from 6000 to 7000 L/min at 0.7 MPa inlet, but keep in mind that 0.4 MPa is 44% of the standard 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
The lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 1/2" port, a 5 um element, a 100 cc drain bowl, a 185 cc oil bowl, and weighs 2390 g. The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32.
The 5 um W element catches far finer particles than the 40 um standard, suiting precision valves and instrument air, though it requires more frequent element service. The L type restricts the ceiling to 0.4 MPa, meaning if the machine may ever need more actuation force, this is the incorrect part.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.