The AirTAC GAC F.R.L. Unit GAC40015STK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatic setups, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in ported body operates within a 0.15-0.9 MPa (20-130 psi) range, utilizing a 40 um element to capture solid particles. A pre-fitted circular gauge reads in MPa/psi for the default NPT thread, while the included reverse-flow (reflux) valve appears as a distinct pneumatic symbol in the catalogue.
The 2390 g assembly is designed for panel or frame mounting rather than tubing support. Condensate accumulates in a 100 cc drain bowl, while the 185 cc oil reservoir supplies downstream lubrication. Because the lubricator sits last in the sequence, oil mist is introduced after the regulator, preventing seat fouling and ensuring stable pressure control. Order code GAC40015STK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC40015STK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds multiple pneumatic torque wrenches and actuators simultaneously, relying on the 1/2in port and 100 cc condensate capacity to handle high continuous air demand.
Provides consistent 0.15-0.9 MPa regulated air and oil mist to moving folding mechanisms and sealing cylinders, extending component life in high-speed packaging operations.
Conditions air for pneumatic pusher arms and sorting gates on distribution conveyors, where the pre-assembled bracket minimizes potential leak paths during operation.
Choose this GAC400 assembly for mid-to-heavy duties where the plotted flow envelope reaches 6000 L/min at 0.7 MPa inlet, offering twice the capacity of the smaller GAC300. The standard PC bowl suits general industrial environments, paired with a semi-auto and manual drain that releases condensate on pressure drops or by hand. If your application requires oil-free output downstream, you must omit the lubricator and select a dedicated filter-regulator instead. Replacement spares follow the body-port suffix strictly: order GAF400-15, GAR400-15 and GAL400-15 as needed. Keep in mind the overpressure margin: the 1.5 MPa proof pressure provides a 1.5x burst-test boundary above the 1.0 MPa maximum, which is a safety rating rather than permission to operate beyond the 1.0 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It features a 100 cc drain bowl, a 185 cc oil bowl, and weighs 2390 g.
The K indicates that a reverse-flow (reflux) valve is fitted to this unit. The catalogue shows this valve as a separate pneumatic symbol with specific details on its own page. This model also includes a standard semi-auto and manual drain setup rather than an automatic one.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.