The AirTAC GAC F.R.L. Unit GAC400C15ALNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC F.R.L. combination pre-assembles a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/2in port GAC400 body carries a 100 cc condensate bowl and a 185 cc oil reservoir, weighing 2390 g overall. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the internal pressure-control mechanisms.
Configured for low-pressure duties, the unit regulates between 0.15-0.4 MPa (20-58 psi) and features a 40 um element. The metal bowl withstands the standard 1.0 MPa (145 psi) maximum operating pressure, while the automatic drain clears liquid condensate without an operator. A reverse-flow (reflux) valve is fitted, shown in the catalogue as a separate pneumatic symbol with details on its own page. No gauge is supplied, but the body retains a 1/4in gauge connection for adding instrumentation later. Order code GAC400C15ALNTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC400C15ALNTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate bagging and sealing actuators where operating pressures must remain under 0.4 MPa to prevent crushing thin films.
Provides consistent, lubricated air to loom and knitting machine cylinders that require gentle pneumatic force to avoid yarn breakage.
Conditions the main 1/2in air supply drop for a multi-station work cell, utilizing the automatic drain for unattended weekend shutdowns.
Choose this 1/2in port model for mid-capacity air preparation where the machine pressure must stay at or below 0.4 MPa. If the application ever requires standard pressure up to 0.9 MPa, this lower-pressure type is the wrong part. The 40 um element suits general plant air, whereas a 5 um version is needed for finer instrument protection. Because no gauge is included, the set pressure cannot be read unless one is added to the 1/4in connection. Should the downstream line require completely dry, oil-free air, omit the lubricator and select a separate filter-regulator instead. For maintenance, the assembly accepts individual GAF400-15, GAR400-15 and GAL400-15 replacement units. Stepping down to the GAC300 shrinks the plotted flow envelope from 6000 L/min to 3000 L/min at 0.7 MPa inlet, halving the available capacity, while the 0.4 MPa ceiling is 44% of the standard 0.9 MPa upper limit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 1/2in port, a 40 um element, a metal bowl, an automatic drain, and a 1/4in gauge connection. The drain bowl holds 100 cc and the oil bowl holds 185 cc. The unit weighs 2390 g, runs on air at -5 to 70 C, and uses ISO VG 32 lubricant.
The K indicates that a reverse-flow (reflux) valve is attached to this specific unit. The official catalogue depicts this component as a separate pneumatic symbol with its functional details located on a dedicated page.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.