The AirTAC GAC F.R.L. Unit GAC400C15AST is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatics, this GAC400C15AST assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a 40 um element and a standard pressure range of 0.15-0.9 MPa (20-130 psi). Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the internal pressure-control mechanisms.
Weighing 2390 g, this size class requires rigid frame mounting rather than tubing support. The metal bowl equips the unit for harsher industrial settings, while the automatic drain empties the 100 cc condensate sump without operator intervention. A circular gauge is fitted, reading MPa/psi for the default NPT thread, allowing direct visual verification of the downstream setpoint.
| Model | Airtac GAC F.R.L. Unit GAC400C15AST |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds main air headers for multi-station welding cells where a 1/2in port sustains high actuator demand and the metal bowl withstands shop-floor debris.
Supplies oil-misted air to high-speed folding cylinders, relying on the automatic drain to purge condensate during non-stop weekend production runs.
Conditions air for pneumatic tool-release mechanisms on machining centers, using the 40 um element to protect precision valve internals from grit.
Choose this 1/2in unit when a mid-to-high flow capacity is required; the catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, exactly double the 3000 L/min envelope of the GAC300. The metal bowl (C) shares the same 1.0 MPa maximum pressure and -5 to 70 C thermal limits as the PC and nylon options, so selection hinges on physical environment rather than pressure capability. The automatic drain (A) clears condensate automatically, a decisive advantage for unattended machinery. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead. For maintenance, the individual components are separately orderable as GAF400-15, GAR400-15 and GAL400-15. Note that the 1.5 MPa proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, which is a safety rating rather than permission to operate above the standard ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. The temperature range is -5 to 70 C. It features a 100 cc drain bowl, a 185 cc oil bowl, a 40 um element, and weighs 2390 g. The recommended lubricant is ISO VG 32 or equivalent.
The automatic drain evacuates condensate from the 100 cc sump whenever it accumulates, eliminating the need for manual intervention on a daily route. The metal bowl provides a robust housing option within the shared -5 to 70 C thermal and 1.0 MPa pressure limits, suited to environments where polycarbonate or nylon bowls might be mechanically impacted.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.