The AirTAC GAC F.R.L. Unit GAC400C15LNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatic setups, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a 2390 g mass, placing it firmly in a mid-to-heavy size class that requires a solid panel or frame mount rather than tubing support. Air passes through the filter first, then the regulator, with oil mist added last so the internal seat never fouls. This specific lower-pressure type regulates between 0.15-0.4 MPa (20-58 psi), while the standard 40 um element captures solid grain.
A metal bowl equips this assembly for rugged industrial surroundings, and the semi-auto plus manual drain pair handles condensate removal. Because the N code follows the port, no pressure gauge is supplied; operators can add one later via the 1/4in gauge connection. If a machine downstream requires strictly oil-free air, omit the lubricator and choose a dedicated filter-regulator instead. Replacement parts map directly to GAF400-15, GAR400-15 and GAL400-15. Order code GAC400C15LNT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC400C15LNT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air to loom cylinders and tensioning actuators where precise, sub-0.4 MPa control prevents fabric damage.
Conditions air for continuous motion folding arms and sealing jaws, relying on the 100 cc drain bowl for prolonged shifts.
Supplies a steady oil mist to heavy chain drives and pneumatic pushers across 1/2in piped distribution headers.
Select this model for 1/2in ported lines operating under 0.4 MPa, where the metal bowl offers durability against incidental contact. Stepping down to the GAC300 reduces the drain bowl to 60 cc, whereas this body holds 100 cc of condensate, extending service intervals. The 40 um element suits general plant air, while the semi-auto drain dumps liquid on every pressure drop. Note that the NPT thread dictates an MPa/psi scale if a gauge is added.
Because the lubricator introduces oil downstream, select a filter-regulator for oil-free applications. When sizing for capacity, remember the catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, exactly double the GAC300's 3000 L/min envelope. Finally, the lower-pressure ceiling of 0.4 MPa is 44% of the standard 0.9 MPa limit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 100 cc drain bowl, a 185 cc oil bowl, a 40 um element, and weighs 2390 g. Use ISO VG 32 or equivalent lubricant.
The N after the port code indicates no gauge is supplied. The 1/4in gauge connection on the body allows you to install a separate gauge if visual pressure monitoring is required for your setup.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.