The AirTAC GAC F.R.L. Unit GAC400C15LWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic machinery, this GAC400C15LWT combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a 5 um element to trap fine particles before they reach sensitive valves, while the lower-pressure type restricts regulation to 0.15-0.4 MPa (20-58 psi). A circular gauge reading MPa/psi is fitted to the NPT thread so operators can verify the setpoint visually.
The metal bowl equips this unit for rugged plant environments, and the 100 cc condensate sump paired with a 185 cc oil reservoir sets the maintenance interval for a 2390 g assembly that requires a firm panel mount rather than tubing support. Air flows through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Condensate is expelled via a semi-auto drain that dumps on every pressure drop, backed by a manual override.
| Model | Airtac GAC F.R.L. Unit GAC400C15LWT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air through a 5 um element to protect sensitive proportional valve banks from particulate ingress on assembly lines.
Supplies a steady 0.4 MPa to heated sealing jaws and their pneumatic actuators, ensuring consistent film overlap without over-pressurizing the cylinders.
Conditions instrument air for low-pressure test rigs, relying on the metal bowl to withstand intermittent cleaning solvents in analytical environments.
Choose this 1/2in model when a machine demands exceptionally clean air at low pressure, as the 5 um element catches far finer particulates than the 40 um standard, albeit requiring more frequent element swaps. The metal bowl offers durability where impacts or solvents might crack standard PC, though buyers must confirm chemical compatibility for aggressive fluids. Because the lubricator injects oil into the downstream line, select a separate filter-regulator instead if your actuators require a dry, oil-free supply. Should a component fail, the assembly breaks down into separately orderable spares: GAF400-15, GAR400-15 and GAL400-15. Stepping down to the GAC300 halves the condensate capacity to 60 cc, whereas this body holds 100 cc; furthermore, the 0.4 MPa ceiling is 44% of the standard 0.9 MPa limit, so never specify the L type if the circuit might need higher pressure later.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 1/2in port, a 5 um element, a metal bowl, and a semi-auto plus manual drain. The temperature range is -5 to 70 C, the condensate bowl holds 100 cc, the oil bowl holds 185 cc, the recommended lubricant is ISO VG 32, and the unit weighs 2390 g.
The W code specifies a 5 um element, which traps far finer particles than the standard 40 um filter, making it ideal for precision pneumatics. The L code limits the regulator to 0.15-0.4 MPa (20-58 psi), meaning if your equipment ever requires more than 58 psi, this specific unit will be the wrong part for the application.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.