The AirTAC GAC F.R.L. Unit GAC400C15SNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatics, this GAC400C15SNWTK assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a 5 um element to capture fine particulates before they reach sensitive valves. Standard type regulation spans 0.15-0.9 MPa (20-130 psi), while the robust metal bowl suits harsher industrial settings.
Air flows through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat stays clean. Because the code includes an N after the port, no gauge is supplied; operators can fit one later using the 1/4in gauge connection. The reverse-flow (reflux) valve is fitted, shown in the catalogue as a separate pneumatic symbol on its own page. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC400C15SNWTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds multi-axis actuators and tool changers where the 5 um element protects precision spool valves from fine machining debris.
Drives high-speed pneumatic grippers and diverter gates, relying on the 1/2in port to sustain adequate volume during rapid cycling.
Conditions air for heavy-duty sheet metal feeders, utilizing the metal bowl to withstand the occasional impact in aggressive production cells.
Choose this 2390 g unit for mid-to-heavy duties requiring a 1/2in port, stepping up from the GAC300 which has a 3000 L/min flow envelope plotted at 0.7 MPa inlet versus the 6000 L/min envelope of this GAC400. The semi-auto and manual drain pair handles the 100 cc condensate bowl, emptying on pressure drops or on demand. If the downstream line must remain completely oil-free, omit the lubricator and select a dedicated filter-regulator instead. Spares for this body-port are GAF400-15, GAR400-15 and GAL400-15. Stepping from the GAC300 to this GAC400 roughly doubles the plotted flow envelope, giving you 2x the sizing headroom at 0.7 MPa inlet.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
The standard type pressure range is 0.15-0.9 MPa (20-130 psi), with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The unit weighs 2390 g, features a 100 cc drain bowl and a 185 cc oil bowl, and requires ISO VG 32 or equivalent lubricant.
The N in the ordering code means no gauge is supplied from the factory, but a 1/4in gauge connection allows you to add one to read the set pressure. The W code specifies a 5 um filtering element, which traps far finer particles than the standard 40 um grade, making it ideal for protecting sensitive instrument air circuits at the cost of more frequent element service.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.