The AirTAC GAC F.R.L. Unit GAC600C20ASWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, pressure-set and oil-misted air to large pneumatic headers, this AirTAC GAC600C20ASWT combines a filter, regulator and lubricator on a single L-shape bracket. The 3/4in port serves high-demand circuits, while the 5 um element captures fine particulates before they reach precision valves. A circular gauge is fitted, reading MPa/psi for the default NPT thread, allowing direct monitoring of the 0.15-0.9 MPa (20-130 psi) operating range.
The metal bowl equips this 4600 g assembly for rugged plant environments, and the automatic drain empties the 205 cc condensate sump without an operator. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat to prevent fouling. For maintenance, the individual GAF600-20, GAR600-20 and GAL600-20 components are separately orderable.
| Model | Airtac GAC F.R.L. Unit GAC600C20ASWT |
|---|---|
| Series | GAC600 F.R.L. combination |
| Port size | 3/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 205 cc |
| Capacity of oil bowl | 410 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 4600 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC600 | GA600 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: Metal (C) only. |
| 20 | Port size 3/4". This body offers 20 = 3/4", 25 = 1". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) only. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF600-20 filter, GAR600-20 regulator, GAL600-20 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC600 · 3/4" · curve to 12000 L/min |
|---|---|
| One size down | GAC500 |
| Build order | Filter → bracket → regulator → lubricator |
Feeds a primary distribution header supplying multiple robotic welding and handling actuators that consume high volumes of prepared air.
Conditions air for continuous diverter gates and pneumatic capping heads where the 5 um element protects tight-clearance valves from grit.
Supplies large-bore clamps and tool changers, relying on the automatic drain to clear condensate during unattended weekend cycles.
Select this 4600 g unit when a machine line requires substantial air flow, as the catalogue flow curve for the GAC600 is plotted to 12000 L/min at 0.7 MPa inlet, exactly double the 6000 L/min envelope of the smaller GAC400. The 5 um element provides stricter filtration than the standard 40 um grade, trading slightly more frequent element service for better protection of sensitive instruments. If the downstream process cannot tolerate oil mist, omit the lubricator and choose a dedicated filter-regulator instead of this combination.
The 410 cc oil bowl and 205 cc drain sump minimize intervention intervals on multi-station lines. Stepping up to this body yields a 1.5x burst-test margin, with its 1.5 MPa proof pressure evaluated against the 1.0 MPa maximum, confirming it is a safety boundary rather than permission to exceed the standard 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. The temperature range is -5 to 70 C. It features a 205 cc drain bowl, a 410 cc oil bowl, uses ISO VG 32 lubricant, and weighs 4600 g.
The GAC600 body is offered with the metal bowl only, providing a robust housing for high-flow industrial settings. The 5 um element traps far finer particles than the standard 40 um filter, making it ideal for protecting precision valves and instrument air, though it requires more frequent element replacement.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.