The AirTAC GAC F.R.L. Unit GAC600C20ST is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for heavy-duty pneumatic systems, the AirTAC GAC600C20ST is a complete F.R.L. combination. It pre-assembles a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 3/4in port serves high-demand circuits, while the standard type provides a 0.15-0.9 MPa (20-130 psi) operating range. A 40 um element captures solid particulates, and the fitted circular gauge reads in MPa/psi for the default NPT thread.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Because this is the largest size class, the 4600 g assembly requires a solid frame mount rather than tubing support. The metal bowl equips this unit for rugged environments, and the 205 cc condensate sump paired with a 410 cc oil reservoir minimizes maintenance interventions. The semi-auto and manual drain pair is fitted as standard.
| Model | Airtac GAC F.R.L. Unit GAC600C20ST |
|---|---|
| Series | GAC600 F.R.L. combination |
| Port size | 3/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 205 cc |
| Capacity of oil bowl | 410 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 4600 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC600 | GA600 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: Metal (C) only. |
| 20 | Port size 3/4". This body offers 20 = 3/4", 25 = 1". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) only. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF600-20 filter, GAR600-20 regulator, GAL600-20 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC600 · 3/4" · curve to 12000 L/min |
|---|---|
| One size down | GAC500 |
| Build order | Filter → bracket → regulator → lubricator |
Feeds a multi-station manufacturing cell where the 3/4in port and large 410 cc oil bowl sustain continuous operation for pneumatic presses and clamps.
Conditions high-volume air for large bore cylinders, relying on the 205 cc drain bowl to capture significant condensate from heavy cycling.
Supplies clean, regulated and lubricated air to a main distribution line, using the fitted gauge to verify a stable 0.9 MPa setting.
Choose this 3/4in body when a machine header or multi-station line demands a high flow capacity, as the catalogue flow curve for the GAC600 is plotted to 12000 L/min at 0.7 MPa inlet. If a smaller circuit is needed, stepping down to the GAC500 keeps the same 3/4in port but reduces the plotted envelope to 7000 L/min. This unit uses a metal bowl, the only material offered for the 600 series, and carries both semi-auto and manual drains. If the application requires oil-free air downstream, the lubricator must be omitted and a separate filter-regulator chosen instead. Replacement spares share the exact same body and port suffix: GAF600-20, GAR600-20 and GAL600-20. Stepping up from the GAC500 gives roughly 1.7x the flow envelope, but also note the overpressure margin: the 1.5 MPa proof pressure against the 1.0 MPa maximum is a 1.5x burst-test margin, not permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It uses a 40 um element, has a temperature range of -5 to 70 C, and uses ISO VG 32 lubricant. The drain bowl holds 205 cc, the oil bowl holds 410 cc, and the assembly weighs 4600 g.
This variant includes both a semi-auto drain, which dumps condensate on each pressure drop, and a manual drain for on-demand emptying. A circular gauge is fitted and reads in MPa/psi to match the NPT thread.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.