The AirTAC GAC F.R.L. Unit GAC600C25ASNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for heavy pneumatic demands, this AirTAC GAC600C25ASNWT F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1in port and 4600 g mass place it in the largest size class, requiring a solid frame mount rather than tubing support. It features a 5 um element for trapping fine particulates ahead of precision valves, operating within a 0.15-0.9 MPa (20-130 psi) standard pressure range.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. This specific build uses a robust metal bowl paired with an automatic drain that clears condensate without an operator, which is decisive for unattended or wet lines. No gauge is supplied, but a 1/4in connection is provided if you need to add one to read the set pressure. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC600C25ASNWT |
|---|---|
| Series | GAC600 F.R.L. combination |
| Port size | 1" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 205 cc |
| Capacity of oil bowl | 410 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 4600 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC600 is 1/4" if you add one.
| GAC600 | GA600 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: Metal (C) only. |
| 25 | Port size 1". This body offers 20 = 3/4", 25 = 1". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) only. |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF600-25 filter, GAR600-25 regulator, GAL600-25 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC600 · 1" · curve to 12000 L/min |
|---|---|
| One size down | GAC500 |
| Build order | Filter → bracket → regulator → lubricator |
Feeds main 1in air headers supplying multiple robotic welding and handling stations, using the 5 um element to protect sensitive end-effectors.
Conditions air for large pneumatic diverters and high-force actuators, relying on the 205 cc automatic drain bowl during continuous wet-duty shifts.
Supplies regulated and lubricated air to heavy-duty clutch and brake cylinders on mechanical presses, ensuring consistent high-volume flow.
Choose this 1in port body for high-flow machine headers, stepping up from the GAC500 which offers a 7000 L/min plotted flow envelope at 0.7 MPa inlet. The GAC600 pushes that sizing envelope to 12000 L/min, accommodating larger multi-station lines. The 5 um W element catches far finer particles than the standard 40 um grade, trading off more frequent element service for cleaner instrument air.
Because the lubricator adds oil mist downstream, pick a separate filter-regulator if the line must remain oil-free. The three units are separately orderable as GAF600-25, GAR600-25 and GAL600-25, so a clogged element or damaged bowl does not require replacing the entire assembly. Stepping from the GAC200 to the GAC600 increases the condensate bowl capacity by 8.2x, scaling from 25 cc to 205 cc.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C, features a 205 cc drain bowl, a 410 cc oil bowl, weighs 4600 g, and uses ISO VG 32 lubricant.
The N in the product code indicates no gauge is supplied. The body features a 1/4in gauge connection, allowing you to install a compatible pressure gauge separately to monitor the 0.15-0.9 MPa operating range.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.