The AirTAC GAC F.R.L. Unit GAC600C25AST is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air straight to a machine header, this GAC600C25AST F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1in port pairs with a 4600 g mass, placing it firmly in the largest size class where rigid panel or frame mounting is required instead of relying on tubing support. Air passes through the 40 um element first, then the regulator sets a 0.15-0.9 MPa (20-130 psi) output, and finally oil mist is introduced downstream so the regulator seat never gets fouled.
A circular gauge is fitted, reading MPa/psi to match the default NPT thread so operators can visually confirm the set pressure. The metal bowl equips this unit for heavy-duty industrial environments, and the automatic drain clears condensate from the 205 cc sump without an operator. The 410 cc oil bowl minimizes refill interventions, while the catalogue flow curve is plotted to 12000 L/min at 0.7 MPa inlet for high-demand sizing.
| Model | Airtac GAC F.R.L. Unit GAC600C25AST |
|---|---|
| Series | GAC600 F.R.L. combination |
| Port size | 1" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 205 cc |
| Capacity of oil bowl | 410 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 4600 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC600 | GA600 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: Metal (C) only. |
| 25 | Port size 1". This body offers 20 = 3/4", 25 = 1". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) only. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF600-25 filter, GAR600-25 regulator, GAL600-25 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC600 · 1" · curve to 12000 L/min |
|---|---|
| One size down | GAC500 |
| Build order | Filter → bracket → regulator → lubricator |
Feeds a primary 1in distribution line supplying multiple pneumatic wrenches and lifts with a steady 0.9 MPa supply and continuous oil mist.
Conditions air for large multi-station filling and capping machines where the 12000 L/min flow envelope easily handles simultaneous actuator demand.
Protects sensitive pneumatic clamps and tool changers by trapping 40 um particulate and regulating pressure precisely before the air reaches the spindle.
Choose this 1in port body for large multi-station lines, stepping down to the GAC500 with its 7000 L/min plotted envelope if the duty point is lighter. The metal bowl is the only option on the GAC600 and handles rugged surroundings, while the automatic drain is decisive for unattended or wet lines. The standard type regulates up to 0.9 MPa; if a machine requires strictly oil-free air downstream, omit the lubricator and choose a separate filter-regulator instead. Replacement spares share the same body and port suffix: GAF600-25, GAR600-25 and GAL600-25. Stepping up from the GAC200 to this GAC600 means the 205 cc drain bowl holds about 8x the condensate, drastically cutting the frequency of manual interventions. The 1.5 MPa proof pressure against the 1.0 MPa maximum provides a 1.5x burst-test margin, not permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C using ISO VG 32 lubricant. It features a 1in port, a 205 cc drain bowl, a 410 cc oil bowl, and weighs 4600 g.
The A in the model code specifies an automatic drain that expels condensate from the 205 cc sump without operator intervention, making it ideal for continuously wet or unattended compressor lines. The metal bowl provides durability in demanding environments where standard PC or nylon bowls might not be specified.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.