The AirTAC GAC F.R.L. Unit GAC600C25SWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for large-scale pneumatic systems, the AirTAC GAC600C25SWT is a complete F.R.L. combination built on a single L-shape bracket. This assembly pairs a filter, regulator and lubricator using quick mounting clamps, eliminating inter-unit tubing and minimizing potential leak paths during commissioning. Outfitted with a 1in port, a 5 um element and a standard pressure range of 0.15-0.9 MPa (20-130 psi), it is designed for heavy-duty air preparation.
The unit features a durable metal bowl and carries a substantial 4600 g mass, requiring a solid panel or frame mount rather than tubing support. A circular gauge is fitted, reading in MPa/psi for the default NPT thread, allowing operators to monitor downstream settings directly. The 5 um filter grade traps fine particles to protect precision valves, while the pre-plumbed configuration ensures oil mist is introduced downstream of the regulator so the regulating seat remains uncontaminated.
| Model | Airtac GAC F.R.L. Unit GAC600C25SWT |
|---|---|
| Series | GAC600 F.R.L. combination |
| Port size | 1" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 205 cc |
| Capacity of oil bowl | 410 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 4600 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC600 | GA600 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: Metal (C) only. |
| 25 | Port size 1". This body offers 20 = 3/4", 25 = 1". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) only. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF600-25 filter, GAR600-25 regulator, GAL600-25 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC600 · 1" · curve to 12000 L/min |
|---|---|
| One size down | GAC500 |
| Build order | Filter → bracket → regulator → lubricator |
Feeds large multi-station machine headers where a 1in port is necessary to supply high volumes of conditioned air to numerous pneumatic actuators simultaneously.
Supplies finely filtered 5 um air to precision tooling and pneumatic clamps, ensuring sensitive valves operate without contamination from fine particulates.
Conditions air for high-speed corrugating or palletizing machinery, utilizing the 410 cc oil bowl to maintain consistent lubrication over extended production runs.
Choose this GAC600 series assembly for high-demand applications requiring significant air flow, as its catalogue flow curve is plotted to 12000 L/min at 0.7 MPa inlet. The metal bowl is standard for this body size, offering robust service in industrial environments. It ships with both a semi-auto and manual drain fitted, meaning condensate is expelled automatically on each pressure drop but can also be purged on demand. Because the lubricator adds oil mist, select a separate filter-regulator if your downstream line must remain strictly oil-free. Should the element clog or a bowl get damaged, you can order spares individually using GAF600-25, GAR600-25 and GAL600-25. The 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin above the 1.0 MPa maximum, but this is strictly a safety rating and not permission to operate above the 1.0 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This unit operates at a standard pressure range of 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It features a 205 cc drain bowl, a 410 cc oil bowl, and weighs 4600 g.
The 5 um element traps far finer solid particles than the standard 40 um grade, making it ideal for protecting precision valves or instrument air circuits. The trade-off is that the finer mesh requires more frequent element service to prevent clogging and maintain optimal flow.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.