The AirTAC GFC200-06 Combination Unit (GFC20006LC1T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC series is a two-piece set - a filter regulator plus a separate lubricator - so one installation filters, regulates and lubricates the compressed air. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum working pressure is 1.0 MPa (145 psi). As a low-pressure type, the set pressure is limited to low-pressure duty; confirm the exact adjustment range with us. The polycarbonate bowls suit -5 to 70 C (non-freezing) air.
This is a genuine AirTAC part. The family spans 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, and catalogue options include automatic or manual drains, the 5 um fine element, square or round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the flow and datasheet figures for your circuit. Order code GFC20006LC1T has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GFC200-06 Combination Unit (GFC20006LC1T) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-06 |
| Build order | Filter regulator first, lubricator last |
Supplies gentle, low-pressure actuation to small test-rig cylinders and sample-handling actuators, with the round MPa gauge giving a clear panel readout of the set point.
Feeds filtered, lubricated low-pressure pilot signals to larger process valves on a skid, where the regulator holds the signal pressure and the gauge lets technicians verify it at a glance.
Runs the light gating and pusher cylinders of a sorting module, keeping delicate low-pressure actuators supplied with clean, oiled air at a stable set pressure.
Choose this low-pressure (L) version when the downstream device needs a set point below the standard range; standard-type GFC sets adjust 0.15-0.9 MPa (20-130 psi) with the differential-pressure drain this unit carries, and we confirm the L-type range on request. The 200 size with NPT1/8 is the smallest port step; use GFC300 (1/4 in) and up for heavier demand. The standard 40 um element fits general circuits; add W to the code for 5 um. This unit has the external round MPa gauge instead of the embedded square one, and no reverse valve. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow appears only as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we cannot honestly quote one number. Share your circuit's air demand and we will confirm the flow for this 200 size with a NPT1/8 port from the datasheet before you order.
L marks the low-pressure regulator type, intended for set points below the standard range. Standard-type GFC sets adjust 0.15-0.9 MPa (20-130 psi) with the differential-pressure drain this unit carries; for the exact low-pressure adjustment range, confirm with us and we will read it from the datasheet.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.