The AirTAC GFC200-06 Combination Unit (GFC20006MLF1T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$59.60 $67.10Save 11% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC200-06 drain, gauge and thread option on one page All GFC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC200-06 Combination Unit (GFC20006MLF1T)

The AirTAC GFC series is a two-unit air-treatment set pairing a filter-regulator with a lubricator, so one assembly removes water and particulate, holds a set downstream pressure and meters oil mist into the air line. This GFC20006MLF1T is the 200 size with NPT1/8 standard ports, a manual drain on the polycarbonate filter bowl, the low-pressure type regulator with a 0.05-0.9 MPa (7-130 psi) adjustment span, the embedded square pressure gauge reading in MPa, and the standard 40 um filtration element. Operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Rated flow is published as curves rather than a single number, so we confirm the datasheet and sizing figures on request.

AirTAC GFC200-06 Combination Unit (GFC20006MLF1T) Technical Specifications

ModelAirTAC GFC200-06 Combination Unit (GFC20006MLF1T)
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC200-06 Combination Unit (GFC20006MLF1T)

GFC200G-series two-unit set, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/8" · 40 µm
One size upGFC300
Three-unit equivalentGC200-06
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC200-06 Combination Unit (GFC20006MLF1T) Is Used

factory

Assembly-cell air prep at the drop header

Mount the set at the air drop of a manual assembly cell so filtered, regulated, lubricated air reaches screwdrivers and clamping fixtures, with the embedded square gauge visible on the panel.

settings_input_component

Pick-and-place gripper supply

Condition the air feeding gripper cylinders and suction ejectors on a handling station, with the low-pressure type regulator set to a gentle pressure for light components.

handyman

Nail gun supply in a truss plant

Feed pneumatic nailers on a truss or framing line with filtered air and oil mist, and drain the bowl by hand as part of the daily start-up check.

Is the AirTAC GFC200-06 Combination Unit (GFC20006MLF1T) the Right Set?

The 200 size with NPT1/8 ports is the compact step of the G series; step to 300/400/600 for larger ports and more flow. The manual drain suits attended installations where the bowl is drained by hand, while automatic and differential-pressure drain codes serve unattended drops. Filtration is the 40 um standard, with the W suffix giving 5 um. Here the gauge is the embedded square type on MPa scale (scale 1); the round external gauge and psi or bar scales are alternative codes. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.

AirTAC GFC200-06 Combination Unit (GFC20006MLF1T) FAQ

Flow for the G series is published as capacity curves, not as a single rated figure, so we do not state a number here. Share your supply pressure, set pressure and downstream demand and we will confirm the sizing from the datasheet on request.

The gauge position F selects the embedded square pressure gauge, here on MPa scale (scale 1). Round external gauges are the alternative body style, and scales 2 and 3 give psi and bar readings. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC200-06 Combination Unit (GFC20006MLF1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC20006MLF1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.