verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC200-06 Combination Unit (GFC20006MNWTK)

The AirTAC GFC200-06 Combination Unit (GFC20006MNWTK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$67.13 $74.63Save 10% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC200-06 drain, gauge and thread option on one page All GFC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC200-06 Combination Unit (GFC20006MNWTK)

The AirTAC GFC series is a two-unit air preparation set: a filter regulator plus a lubricator, giving filtration, pressure regulation and oil-mist lubrication in one station. This GFC20006MNWTK is the 200 size with NPT 1/8 ports, a manual drain on the filter bowl, a 5 um filter element, no gauge fitted, and a reverse (check) valve specified by the trailing K. The manual drain means water is emptied from the bowl by hand, and the 5 um element captures finer particulate than the standard 40 um grade. Downstream pressure is set on the regulator within the manual-drain range of 0.05-0.9 MPa (7-130 psi), with a maximum working pressure of 1.0 MPa (145 psi).

This is a genuine AirTAC part. The G series comes in 200, 300, 400 and 600 sizes with ports from 1/8" to 1", 40 um standard or 5 um (W) filter grades, differential-pressure, automatic or manual drains, gauge options, and three thread types (NPT on this code). Working temperature is -5 to 70 C (non-freezing) and the 200-size bowls are polycarbonate. Flow is published as curves rather than a single rating, so we confirm datasheet and flow figures for your circuit on request.

AirTAC GFC200-06 Combination Unit (GFC20006MNWTK) Technical Specifications

ModelAirTAC GFC200-06 Combination Unit (GFC20006MNWTK)
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/8" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC200-06 Combination Unit (GFC20006MNWTK)

GFC200G-series two-unit set, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/8" · 5 µm
One size upGFC300
Three-unit equivalentGC200-06
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC200-06 Combination Unit (GFC20006MNWTK) Is Used

bolt

Fixture clamping on assembly cells

In a fixture-clamping circuit on an assembly cell, the regulator holds the clamp pressure and the specified check valve addresses circuits where reverse flow must be prevented; the lubricator feeds the clamp cylinders.

settings_input_component

Pick-and-place gantry stations

On a pick-and-place gantry with gripper cylinders and vacuum ejector feeds, this set conditions the branch line: 5 um filtration, regulated pressure at each station and oil mist for the actuators.

factory

Bench-mounted pneumatic press feed

At a small pneumatic bench press, the set sits at the drop: the regulator sets working pressure, the 5 um element protects the valve stack, and the lubricator conditions the press cylinder.

Is the AirTAC GFC200-06 Combination Unit (GFC20006MNWTK) the Right Set?

Step up from 200 to 300, 400 or 600 when your circuit needs larger ports and more flow; this 200 size with NPT 1/8 ports suits compact circuits. The trailing K specifies a reverse (check) valve with the unit; the same code without K is the standard build. The manual drain (M) suits stations where an operator can empty the bowl during checks; automatic (A) and the default differential-pressure drain are also offered. Keep the W code for the 5 um element or drop it for 40 um. No gauge is fitted on this code; square embedded and round external gauges with MPa, psi or bar scale are available in other variants. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating - ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.

AirTAC GFC200-06 Combination Unit (GFC20006MNWTK) FAQ

AirTAC publishes flow for the G series as characteristic curves rather than a single rated figure, so there is no one number to quote. Send us your circuit details and we will confirm the datasheet curve and check the 200 size with NPT 1/8 ports against your application before ordering.

K specifies a reverse (check) valve fitted with the unit; the equivalent code without K, GFC20006MNW, has none. Everything else decodes identically: 200 size, NPT 1/8 ports, manual drain, 5 um element and no gauge. If you prefer hands-off water removal, ask about the A-drain variant.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC200-06 Combination Unit (GFC20006MNWTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC20006MNWTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.