The AirTAC GFC200-06 Combination Unit (GFC20006NWTK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC20006NWTK is a genuine AirTAC two-unit air-treatment set: a filter regulator combined in one body, paired with a lubricator, filtering, regulating and oil-mist lubricating compressed air in one setup. The trailing K adds a reverse (check) valve. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Regulation range with the differential-pressure drain is 0.15-0.9 MPa (20-130 psi); maximum inlet pressure is 1.0 MPa (145 psi). Both 200-size bowls are polycarbonate (PC), and the working temperature range is -5 to 70 C (non-freezing).
AirTAC builds the G series in 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in and three thread types (NPT on this code), plus drain-style, filtration-grade, gauge and mounting options. Flow for the series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet and flow figures for GFC20006NWTK on request.
| Model | AirTAC GFC200-06 Combination Unit (GFC20006NWTK) |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-06 |
| Build order | Filter regulator first, lubricator last |
Conditions air for solenoid valve manifolds on form-fill-seal machines, with the check valve helping the downstream circuit hold its set pressure between cycles and the 5 um element guarding the valve seats.
Supplies filtered, regulated, lubricated air to light clamping fixtures on machining benches, where the fitted check valve supports holding the clamp circuit after the supply is shut off.
Feeds precision air-jet blowing stations on production benches, delivering dry, pressure-stable and oiled air through a compact 1/8 in connection.
Choose this code over plain GFC20006NW when you want the reverse (check) valve fitted, useful where downstream pressure should be held. The 200 size with NPT1/8 port is the smallest G-series step; move to 300, 400 or 600 if your demand outgrows it. The 5 um (W) element gives finer filtration than the standard 40 um. Drain is the differential-pressure type; automatic (A) or manual (M) drains can be ordered instead, and the manual-drain version widens regulation to 0.05-0.9 MPa. No gauge is fitted (N); square and round gauges in MPa, psi or bar scales are options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating, so let us confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.
AirTAC states G-series flow performance as curves, not as a single rated figure, so we do not quote a rated flow. Share your working pressure and consumption and we will confirm the datasheet and flow curve for this set, including the effect of the check valve, on request.
K means a reverse (check) valve is fitted in the set. Without the K the same two-unit filter regulator and lubricator is supplied without the check valve, so order the K version when you want downstream pressure retained in the circuit.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.