verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-08 Combination Unit (GFC30008ALNT)

The AirTAC GFC300-08 Combination Unit (GFC30008ALNT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$86.86 $94.36Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-08 Combination Unit (GFC30008ALNT)

The GFC series pairs a filter regulator - removing water and particulate from compressed air while holding downstream pressure - with a separate lubricator that meters an oil mist to air tools. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The L suffix marks the low-pressure type; with the automatic drain the quoted adjust range is 0.15-0.9 MPa (20-130 psi), and we confirm the exact low-pressure span on request. Maximum working pressure is 1.0 MPa (145 psi); temperature range is -5 to 70 C, non-freezing. Filter grade is 40 um standard or 5 um with W, drains come as differential-pressure, automatic or manual, and gauge-equipped variants exist where a local pressure readout is wanted. Because rated flow is published as curves, not a single figure, we confirm datasheet data on request. Order code GFC30008ALNT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC300-08 Combination Unit (GFC30008ALNT) Technical Specifications

ModelAirTAC GFC300-08 Combination Unit (GFC30008ALNT)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-08 Combination Unit (GFC30008ALNT)

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-08 Combination Unit (GFC30008ALNT) Is Used

handyman

Woodshop nailer drop

Filtering, regulating and lubricating the branch feeding nailers and staplers at a furniture workshop bench, with the automatic drain handling overnight condensate.

view_module

Parcel sorter diverter supply

Conditioning air to the diverter and pusher cylinders on a parcel-sort conveyor, where pressure is read at the room's main panel rather than at each unit.

science

Lab automation actuators

Supplying clean, regulated, oil-misted air to the gripper and lift cylinders of a laboratory sample-handling station built into a closed cabinet.

Is the AirTAC GFC300-08 Combination Unit (GFC30008ALNT) the Right Set?

Pick the size - 200, 300, 400 or 600 - for the flow and port your circuit requires; this unit is size 300 on NPT1/4. Drain types are automatic (fitted here), manual, and the differential-pressure default. Filtration is the standard 40 um; order the W variant for 5 um where finer protection matters. The N code means no gauge, ideal for concealed panels or circuits that read pressure elsewhere - choose a square-gauge code in MPa, psi or bar scales when a local readout helps. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves rather than one rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

AirTAC GFC300-08 Combination Unit (GFC30008ALNT) FAQ

Flow for the GFC series is published as characteristic curves, not as a single rated figure, so we do not state a number here. Share your application - the devices served and their air demand - and we will confirm the datasheet curve and sizing on request before you order.

N is the no-gauge code: the regulator is supplied without a pressure gauge, which suits panels that display pressure elsewhere. Gauge-equipped variants use the embedded square gauge in MPa, psi or bar scales, so you can switch codes whenever a local readout is wanted.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-08 Combination Unit (GFC30008ALNT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30008ALNT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.