The AirTAC GFC300-08 Combination Unit (GFC30008ALNWT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
This GFC two-unit set combines a filter regulator - removing water and particulate from compressed air and regulating downstream pressure - with a separate lubricator that feeds an oil mist to air tools. The configuration here is the 300 size with NPT1/4 ports, an automatic drain that discharges condensate unattended, the finer 5 um filter element (W code), the L low-pressure regulator type, and the N no-gauge option. The L suffix marks the low-pressure type; with the automatic drain the quoted adjust range is 0.15-0.9 MPa (20-130 psi), and we confirm the exact low-pressure span on request. Maximum working pressure is 1.0 MPa (145 psi); the service range is -5 to 70 C, non-freezing.
It is a genuine AirTAC part supplied by airtacdistr.com across the 200/300/400/600 sizes with 1/8" to 1" ports, three thread types (NPT on this code) to order. Series options cover 40 um standard or 5 um filtration, differential-pressure, automatic or manual drains, and gauge variants with embedded square dials in MPa, psi or bar. Flow is published as curves, not a single rating, so we confirm datasheet and sizing figures on request. Order code GFC30008ALNWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GFC300-08 Combination Unit (GFC30008ALNWT) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/4" · 5 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-08 |
| Build order | Filter regulator first, lubricator last |
Feeding filtered, regulated, lubricated air to solenoid-piloted process valves on a chemical dosing skid, with the 5 um element guarding the pilot circuits.
Supplying oil-misted air to the reciprocating cylinders of a high-cycle carton feed unit, where automatic draining keeps condensate off the mechanism.
Serving as the compact two-unit prep station inside a control panel that feeds several branch circuits, with pressure monitored at the master gauge.
Choose the size - 200, 300, 400 or 600 - to match required flow and porting; this set is size 300 with NPT1/4 threads. Drain options are automatic (fitted here) for unattended duty, manual, and the differential-pressure default. Filtration is the W-coded 5 um element, the right pick when downstream valves and cylinders need finer protection than the standard 40 um. The N code omits the gauge; square-gauge variants in MPa, psi or bar scales are there when a local readout is wanted. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.
AirTAC publishes GFC-series flow as characteristic curves, not as a single rated figure, so we do not quote a number here. Tell us what the unit will feed and we will confirm the datasheet curve and sizing on request before you order.
The W code gives a 5 um element, which suits circuits with fine pilot valves, sensitive actuators or sealing faces where finer particulate removal pays off; the standard 40 um element covers general plant air. Both grades exist across the GFC series, so pick per branch rather than one grade for the whole plant.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.