The AirTAC GFC300-08 Combination Unit (GFC30008C2T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC30008C2T is a two-piece air-treatment set from AirTAC's G series: a size 300 filter regulator paired with a size 300 lubricator on 1/4 in NPT ports. The filter stage strips water and 40 um particulate into a polycarbonate bowl with a differential-pressure drain, the regulator holds downstream pressure anywhere in its 0.15-0.9 MPa (20-130 psi) adjust range, and the lubricator meters oil mist to downstream tooling. Maximum inlet pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing. This configuration includes an external round gauge reading in psi.
This is a genuine AirTAC part. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application.
| Model | AirTAC GFC300-08 Combination Unit (GFC30008C2T) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/4" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-08 |
| Build order | Filter regulator first, lubricator last |
Feeds the pneumatically piloted diverter and stopper valves on a bottle line. The filter stage takes water and particulate out of the plant air, the regulator holds a steady pilot pressure, and the lubricator keeps valve seals and spools running smoothly shift after shift.
Supplies the blow-off nozzles that clear dust and film trim from packages moving down a conveyor. Clean, regulated, oil-misted air keeps nozzle internals from gumming up and the jet pattern consistent along the line.
Runs the air clamps and swing cylinders on a CNC fixture. The regulator pins clamp pressure so parts seat identically every cycle, the 40 um element protects the cylinder bores, and the lubricator extends seal life in continuous production.
Size 300 with 1/4 in NPT ports is the mid step of the G range; if your line's air demand sits near the top of what a 300 can pass, step up to size 400 rather than undersizing. Drain choice: differential-pressure (this code, standard), automatic (A) for unattended drainage, or manual (M) where you bleed on schedule - note that manual-drain versions widen the regulator adjust range to 0.05-0.9 MPa (7-130 psi). Element grade is 40 um standard or 5 um with code W. This code carries a round gauge in psi; bar and square-MPa variants exist as separate codes. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. a mounting bracket is optional. Because flow is published as curves and not a single rating, send us your pressure and demand figures and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.
AirTAC publishes G-series flow as performance curves, not as a single rated figure, so we do not quote one number here. Give us your operating pressure and air demand and we will read the datasheet curve and confirm the sizing on request before you order.
This code's differential-pressure drain bleeds collected condensate automatically as pressure differential builds, with no operator attention. A manual-drain set (code M) is emptied by hand on a schedule, and manual-drain versions widen the regulator adjust range to 0.05-0.9 MPa (7-130 psi) instead of 0.15-0.9 MPa (20-130 psi).
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.