The AirTAC GFC300-08 Combination Unit (GFC30008F3WT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series pairs a filter-regulator with a lubricator in one two-unit set, so a single assembly cleans the air, fixes the working pressure and supplies oil mist downstream. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
This is a genuine AirTAC part. Flow is published as curves, not a single rating, so we confirm sizing and datasheet figures on request. Order code GFC30008F3WT has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GFC300-08 Combination Unit (GFC30008F3WT) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/4" · 5 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-08 |
| Build order | Filter regulator first, lubricator last |
Fine 5 um filtration, set pressure and light oiling for the small cylinders and ejectors of a PCB pick-and-place or test bench fed at 1/4in.
A conditioned 1/4in supply for assembly-bench screwdriving spindles, keeping grit out of the clutch mechanisms while the lubricator mists the motor.
Prep air inside an instrument cabinet or pilot rig where fine particulate must be removed before it reaches reference-air components.
Size by port and demand: this 300 unit gives a NPT1/4 connection, with 200, 400 and 600 sizes stepping the port and flow capability up or down. The differential-pressure drain here sheds condensate while air is flowing; automatic and manual drains are orderable alternatives, and the drain type sets the regulator range (differential and auto: 0.15-0.9 MPa / 20-130 psi; manual: 0.05-0.9 MPa / 7-130 psi). The 5 um W element is the reason to pick this variant over the standard 40 um - use it when the downstream valves or tools are sensitive to fine particulate.
This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.
AirTAC publishes G-series flow as curves rather than a single rated number, so we do not state a figure here. Share your working pressure and air consumption and we will confirm the fit from the datasheet curves on request before you order.
The W selects the fine 5 um filter element in place of the standard 40 um element - everything else about the set is the same. If your application is general plant air, the non-W version with the 40 um element is the usual choice.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.