verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-08 Combination Unit (GFC30008LC1T)

The AirTAC GFC300-08 Combination Unit (GFC30008LC1T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$80.56 $88.06Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-08 Combination Unit (GFC30008LC1T)

GFC30008LC1T is a two-piece AirTAC G-series air-treatment set: a filter-regulator paired with a lubricator, so the downstream circuit receives filtered, regulated and oil-mist-lubricated compressed air from NPT1/4 (1/4 inch) ports. The regulator is the low-pressure type for circuits that run well below standard line pressure, the 40 um element with differential-pressure drain removes water and particulate, and the set is fitted with an external round pressure gauge scaled in MPa.

This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with 1/8 to 1 inch ports, and options across the family include automatic or manual drains, a 5 um filter element, square or round gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet figures on request.

AirTAC GFC300-08 Combination Unit (GFC30008LC1T) Technical Specifications

ModelAirTAC GFC300-08 Combination Unit (GFC30008LC1T)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-08 Combination Unit (GFC30008LC1T)

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-08 Combination Unit (GFC30008LC1T) Is Used

factory

Packaging line clamp cylinders

Supplying low-pressure, lubricated air to the clamp and hold-down cylinders on a carton-sealing line, where the low-pressure regulator keeps actuation gentle and the oil mist protects cylinder seals.

air

Wood-finishing spray guns

Feeding spray guns in a furniture-finishing booth that run below standard line pressure; the 40 um filter keeps particulate out of the finish and the lubricator protects the gun's air valve.

conveyor_belt

Conveyor cleaning air nozzles

Running product-separation and cleaning nozzles along a food-packaging conveyor, fed with filtered, regulated and lubricated air set below the main line pressure.

Is the AirTAC GFC300-08 Combination Unit (GFC30008LC1T) the Right Set?

Both units here are size 300 with NPT1/4 (1/4 inch) ports; step up to 400 or 600, or down to 200, when the application calls for a larger or smaller port. The filter-regulator bowl drains by the differential-pressure default, and automatic (A) or manual (M) versions can be ordered; the 300-size bowl is polycarbonate. The 40 um element is standard - the W suffix gives a 5 um element. This code carries an external round gauge on the MPa scale; square-gauge versions and psi or bar scales exist in the family. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering, including the exact adjustment range of the low-pressure regulator for your setpoint.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

AirTAC GFC300-08 Combination Unit (GFC30008LC1T) FAQ

Flow for this size is published by AirTAC as performance curves rather than a single rated figure, so we do not quote a number here. Send us your operating pressure and air demand and we will confirm the flow from the datasheet and check the sizing for your application.

L marks the low-pressure regulator type, intended for circuits set below standard line pressure; we confirm the exact adjustment range for your setpoint on request. C means the set carries an external round pressure gauge and 1 is the MPa scale. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT versions can be ordered.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-08 Combination Unit (GFC30008LC1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30008LC1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.