
The AirTAC GFC300-08 Combination Unit (GFC30008LC1T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC30008LC1T is a two-piece AirTAC G-series air-treatment set: a filter-regulator paired with a lubricator, so the downstream circuit receives filtered, regulated and oil-mist-lubricated compressed air from NPT1/4 (1/4 inch) ports. The regulator is the low-pressure type for circuits that run well below standard line pressure, the 40 um element with differential-pressure drain removes water and particulate, and the set is fitted with an external round pressure gauge scaled in MPa.
This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with 1/8 to 1 inch ports, and options across the family include automatic or manual drains, a 5 um filter element, square or round gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet figures on request.
| Model | AirTAC GFC300-08 Combination Unit (GFC30008LC1T) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/4" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-08 |
| Build order | Filter regulator first, lubricator last |
Supplying low-pressure, lubricated air to the clamp and hold-down cylinders on a carton-sealing line, where the low-pressure regulator keeps actuation gentle and the oil mist protects cylinder seals.
Feeding spray guns in a furniture-finishing booth that run below standard line pressure; the 40 um filter keeps particulate out of the finish and the lubricator protects the gun's air valve.
Running product-separation and cleaning nozzles along a food-packaging conveyor, fed with filtered, regulated and lubricated air set below the main line pressure.
Both units here are size 300 with NPT1/4 (1/4 inch) ports; step up to 400 or 600, or down to 200, when the application calls for a larger or smaller port. The filter-regulator bowl drains by the differential-pressure default, and automatic (A) or manual (M) versions can be ordered; the 300-size bowl is polycarbonate. The 40 um element is standard - the W suffix gives a 5 um element. This code carries an external round gauge on the MPa scale; square-gauge versions and psi or bar scales exist in the family. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering, including the exact adjustment range of the low-pressure regulator for your setpoint.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.
Flow for this size is published by AirTAC as performance curves rather than a single rated figure, so we do not quote a number here. Send us your operating pressure and air demand and we will confirm the flow from the datasheet and check the sizing for your application.
L marks the low-pressure regulator type, intended for circuits set below standard line pressure; we confirm the exact adjustment range for your setpoint on request. C means the set carries an external round pressure gauge and 1 is the MPa scale. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT versions can be ordered.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.