The AirTAC GFC300-08 Combination Unit (GFC30008LNT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC30008LNT is an AirTAC G-series two-unit air preparation set: a filter regulator and a lubricator supplied as a pair, so one order covers filtration, pressure regulation and oil-mist lubrication on a 1/4 in NPT line. This 300-size configuration is a low-pressure (L) regulator type with the standard 40 um filter element, a differential-pressure drain on the filter bowl and no gauge (N code). Maximum working pressure is 1.0 MPa (145 psi), and for the differential-pressure drain version the regulator setting range is 0.15-0.9 MPa (20-130 psi).
This is a genuine AirTAC part. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Operating temperature is -5 to 70 C (non-freezing), and the bowls on this 300-size set are polycarbonate. AirTAC publishes flow as curves rather than a single rated figure, so we confirm the datasheet and sizing for your application on request.
| Model | AirTAC GFC300-08 Combination Unit (GFC30008LNT) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/4" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-08 |
| Build order | Filter regulator first, lubricator last |
Feeds the cylinder circuit of a small stamping or clinching press: filtered, regulated air at a stable set pressure plus oil mist to keep the cylinder seals and valve spools lubricated through continuous cycles.
Sits at the drop of a multi-station assembly bench supplying impact drivers, nutrunners and air ratchets, with the lubricator protecting the tool motors and the regulator holding a consistent working pressure.
Prepares air for the gripper and sealing cylinders on a cartoning or case-packing machine, where the two-unit set keeps water and particles out of the valves while metering oil to the actuators.
Start with size and port: 300 gives a 1/4 in port here, and stepping to 200, 400 or 600 changes both port and flow capacity. On the filter side pick the standard 40 um element or the finer 5 um (W) option, and choose the drain: differential-pressure (as in this code), automatic (A) or manual (M). Units with a regulator can carry an embedded square gauge or an optional external round gauge in MPa, psi or bar scale; the N in GFC30008LNT deletes the gauge entirely. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Flow is published as curves, not a single rated figure, so send us your line pressure and air consumption and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.
AirTAC publishes flow for the G-series as characteristic curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and required consumption and we will confirm the correct size and the curve data from the datasheet on request.
L marks the low-pressure regulator type, and N means the set is ordered without a gauge (a square or round gauge can be added as a catalogue option). The code also leaves the drain position blank, which gives the default differential-pressure drain on the filter bowl and the standard 40 um filter element.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.