verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-08 Combination Unit (GFC30008MF1TK)

The AirTAC GFC300-08 Combination Unit (GFC30008MF1TK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$95.49 $102.99Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-08 Combination Unit (GFC30008MF1TK)

The AirTAC GFC300 series pairs a filter regulator with a lubricator as one two-unit set, so a single compressed-air line is filtered, regulated and oiled. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum working pressure is 1.0 MPa (145 psi); with the manual drain fitted, the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi). The 300-size bowls are polycarbonate, and the set operates from -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, three thread types (NPT on this code), plus drain, filter-grade, gauge, bracket and reverse-valve choices. AirTAC publishes flow as curves rather than a single rating, so ask us and we will confirm the datasheet and sizing figures for your application on request. Order code GFC30008MF1TK has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC300-08 Combination Unit (GFC30008MF1TK) Technical Specifications

ModelAirTAC GFC300-08 Combination Unit (GFC30008MF1TK)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-08 Combination Unit (GFC30008MF1TK)

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-08 Combination Unit (GFC30008MF1TK) Is Used

engineering

Welding fixture hold clamps

On a robotic welding cell, swing clamps must stay closed while the weld runs; the reverse valve in this set helps hold downstream pressure through upstream dips, while the filter and regulator keep the clamp cylinders on spec.

precision_manufacturing

Press-feed air counterbalances

On a stamping press feed line, air counterbalance and hold-down circuits depend on stable pressure; this unit conditions the supply, sets the balance pressure on the MPa gauge and oils the cylinders over long production runs.

science

Lab autoclave and rig services

In a test laboratory, pneumatically loaded rigs and door interlocks on chambers need clean, steady air; the 40 um element and set pressure protect the rig instrumentation, and the check valve guards the circuit during supply dips.

Is the AirTAC GFC300-08 Combination Unit (GFC30008MF1TK) the Right Set?

Pick the 300 size with NPT1/4 ports for mid-range supply branches, moving to 200 or 400/600 as your port and air demand dictate. The manual drain suits bowls you can reach for a regular drain; select the A (automatic) or blank (differential-pressure) version elsewhere, with the regulator adjust range differing by drain type. The 40 um element here is the standard grade; order the W option for 5 um fine filtration. This K version adds the reverse (check) valve, useful where a cylinder or clamp must hold its position through an upstream pressure dip; the non-K code omits it. Gauge (square MPa here), thread (NPT on this code) and bracket are selectable. Flow is published as curves, not a single rating, so ask us to confirm sizing against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

AirTAC GFC300-08 Combination Unit (GFC30008MF1TK) FAQ

AirTAC publishes G-series flow as curves, not as a single rated figure, so we do not state a number here. Give us your working pressure and the air consumption of your circuit, and we will confirm the flow curve and datasheet for this exact set on request.

K means a reverse (check) valve is fitted, so downstream pressure is held if the upstream supply drops. The equivalent code without the K omits it; choose K where a clamp or cylinder must not lose position during a pressure dip.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-08 Combination Unit (GFC30008MF1TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30008MF1TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.