verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-08 Combination Unit (GFC30008MF3TK)

The AirTAC GFC300-08 Combination Unit (GFC30008MF3TK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$95.49 $102.99Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-08 Combination Unit (GFC30008MF3TK)

The AirTAC GFC series combines a filter-regulator and a lubricator into one two-piece set, so a single code filters, regulates and oil-mist lubricates compressed air. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Manual-drain polycarbonate bowls are emptied by hand, the square gauge shows set pressure in bar, the check valve (K) blocks backflow through the set, and the manual-drain regulator spans 0.05-0.9 MPa (7-130 psi) of setting range.

This is a genuine AirTAC part. The G series runs in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in; At 300 size the bowls are polycarbonate and service is -5 to 70 C non-freezing. Flow for the series is published as curves rather than a single rated figure, so ask us to confirm sizing and the datasheet on request. Order code GFC30008MF3TK has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC300-08 Combination Unit (GFC30008MF3TK) Technical Specifications

ModelAirTAC GFC300-08 Combination Unit (GFC30008MF3TK)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, bar scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-08 Combination Unit (GFC30008MF3TK)

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-08 Combination Unit (GFC30008MF3TK) Is Used

conveyor_belt

Conveyor diverter controls

Runs the pusher and diverter cylinders that divert cartons on a conveyor line, with regulated pressure and a steady oil mist to the cylinders.

settings_input_component

Machine air drop

Serves as the prep set at a 1/4 in machine drop feeding general actuators, with bar-reading pressure visible on the square gauge.

handyman

Impact tool station

Filters, regulates and lubricates air for air ratchets and impact wrenches at a maintenance bench, keeping tool motors oiled.

Is the AirTAC GFC300-08 Combination Unit (GFC30008MF3TK) the Right Set?

The 3 gauge scale in this code gives a bar-reading square gauge - pick it when the rest of the plant reads pressure in bar; MPa (1) and psi (2) scales are the other options. The 40 um element is the standard grade and suits general machine air; step to the W code for 5 um where cleaner air is needed. Manual drain suits attended stations, while automatic and differential-pressure codes serve unattended lines. The K adds the check valve. Size 300 with a 1/4 in NPT port sits mid-series; flow is only published as curves, so have us confirm your sizing against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

AirTAC GFC300-08 Combination Unit (GFC30008MF3TK) FAQ

No single rated number exists in the catalogue for this set - flow is published as characteristic curves. Share your air demand and working pressure and we will confirm the sizing against the datasheet on request.

The gauge scale is a real code choice: 3 in this code gives a square gauge reading in bar, 1 gives MPa and 2 gives psi. Match the scale to what your technicians and local gauges read so set pressures are checked without conversion. The rest of the decode - 300 size, 1/4 in NPT, manual drain, 40 um element, check valve - is unchanged.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-08 Combination Unit (GFC30008MF3TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30008MF3TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.