The AirTAC GFC300-08 Combination Unit (GFC30008MLNT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GFC series is a two-unit air-treatment set: a filter regulator plus a separate lubricator, delivering filtration, pressure regulation and oil-mist lubrication in one line. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
This is a genuine AirTAC part. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing figures for your application on request. Order code GFC30008MLNT has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GFC300-08 Combination Unit (GFC30008MLNT) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/4" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-08 |
| Build order | Filter regulator first, lubricator last |
Regulating and lubricating the air to tipper-cylinder control valves on a bulk transport vehicle, where the gaugeless build suits an already-gauged driver panel.
Installed on branch drop legs feeding general pneumatic equipment in a factory, providing standard 40 um filtration, low-pressure regulation and oil mist without duplicating local gauges.
Fitted to a mobile maintenance trolley that supplies air tools and jacks around the workshop, with manual draining built into the daily check routine.
Choose the 300/1/4 in step for general supply duty; step to 400 or 600 for larger ports and higher flow, or 200 for tight spaces. The N build omits the gauge, ideal where pressure is read remotely or on a panel instrument already in place; otherwise the square MPa gauge is the embedded standard, with round external gauges and psi or bar scales available. The manual drain suits attended maintenance routines, while automatic and differential-pressure drains cover unattended lines. The 40 um element is the general-purpose grade, with 5 um as the finer W option.
Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G(BSPP) and NPT are catalogue options to specify at order time.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.
Flow for the GFC300 series is published as curves rather than a single rated figure, so we do not quote one number. Share your flow requirement with us and we will confirm the correct sizing from the datasheet on request before you order.
N means no pressure gauge is fitted, so the set is supplied gaugeless for use where a panel meter or downstream instrument already shows the pressure. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.