verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015ALF1WT)

The AirTAC GFC400-15 Combination Unit (GFC40015ALF1WT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$137.82 $145.32Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC400-15 Combination Unit (GFC40015ALF1WT)

GFC40015ALF1WT is an AirTAC G-series two-unit air-treatment set: a GFR400 filter-regulator paired with a GL400 lubricator, covering filtration, pressure regulation and oil-mist lubrication in two pieces. This configuration is sized for 1/2 in. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. It is the low-pressure (L) type and comes with a square gauge reading in MPa. Maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C, non-freezing. At size 400 the bowls on both units are PC (polycarbonate).

This is a genuine AirTAC part from the GFC series. The same set is offered in sizes 200, 300, 400 and 600 with a choice of three thread types (NPT on this code), differential-pressure, automatic or manual drains, 40 um or 5 um (W) filtration, and round or square gauges in MPa, psi or bar scales. AirTAC publishes flow for these units as curves rather than a single rated figure, so we confirm flow and full datasheet details for your application on request.

AirTAC GFC400-15 Combination Unit (GFC40015ALF1WT) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015ALF1WT)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015ALF1WT)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 5 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015ALF1WT) Is Used

build

Robot end-effector air supply

Conditioning compressed air feeding a robot cell's pneumatic grippers and tool clamp circuits, with fine filtration and lubrication set at the cell's 1/2 in. supply.

tune

Textile machine air preparation

Treating the supply air to a textile machine's pneumatic thread-tension and doffer actuators, where regulated, lubricated air is taken off a 1/2 in. branch.

shield

Instrument-air branch protection

A fine-filtration point ahead of pilot-operated controls on a process skid, keeping particulates out of sensitive low-pressure pilot lines fed from the 1/2 in. main.

Is the AirTAC GFC400-15 Combination Unit (GFC40015ALF1WT) the Right Set?

Size and port come first: 400 with 1/2 in. NPT suits mid-size plant air take-offs; step up to 600 (1 in.) or down to 300 or 200 if your line volume differs - match the step to required flow, which we confirm from the flow curves before you order. Drain choice: automatic empties the filter bowl without operator attention; manual gives deliberate control; the differential-pressure default triggers on pressure drop. Filter grade: the W suffix here selects the 5 um element for finer particulate protection than the 40 um standard. Gauge: this set carries the square gauge on the 1 (MPa) scale; the round-gauge (C) variant and psi or bar scales are orderable. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G and NPT are catalogue options.

As the low-pressure (L) type, the catalogue adjustment range quoted for the automatic-drain version is 0.15-0.9 MPa (20-130 psi); we confirm the L-type adjustment limits against the datasheet on request before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015ALF1WT) FAQ

AirTAC publishes flow for this series as curves, not as a single rated figure, so sizing is a confirmation rather than a quoted number. Share your working pressure and air demand and we will confirm the flow from the datasheet on request, including whether 400 size at 1/2 in. fits your machine.

Choose W when the downstream equipment needs finer particulate protection than the 40 um standard element provides - for example pilot circuits or precision actuators. The rest of the code stays the same: 400 size, 1/2 in. NPT port, automatic drain, low-pressure type and square MPa gauge. We confirm datasheet details on request.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015ALF1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC40015ALF1WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.