AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015C1T)

The AirTAC GFC400-15 Combination Unit (GFC40015C1T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$124.12 $131.62Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC400-15 Combination Unit (GFC40015C1T)

The AirTAC GFC series is a two-unit F.R.L. set combining a filter-regulator and a lubricator, so compressed air is filtered, regulated and oil-misted in one assembly. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. This configuration specifies an external round pressure gauge with MPa scale instead of the embedded square gauge. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator covers 0.15-0.9 MPa (20-130 psi), the PC (polycarbonate) bowls suit -5 to 70 C (non-freezing) service.

This is a genuine AirTAC part in the G series range (sizes 200/300/400/600, ports from 1/8 to 1 inch), with catalogue options including automatic or manual drains, 5 um elements, square embedded gauges, and G (BSPP) or NPT threads. Flow is published as curves rather than a single rated figure, so send us your application details and we will confirm the datasheet and sizing figures on request. Order code GFC40015C1T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC400-15 Combination Unit (GFC40015C1T) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015C1T)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015C1T)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015C1T) Is Used

conveyor_belt

Conveyor diverting actuators

Running diverters, stops and pushers along a conveyor line, where the 40 um element covers general actuator duty and the external round MPa gauge mounts where operators can read it.

settings_input_component

Textile machine control air

Feeding solenoid valves and small cylinders on weaving and knitting machines, with the differential-pressure drain discharging collected water as pressure drop builds across the element.

precision_manufacturing

Palletising robot gripper supply

Conditioning air to gripper cylinders and tooling on palletising cells, bringing regulation and oil-mist lubrication into the same two-unit set beside the filter.

Is the AirTAC GFC400-15 Combination Unit (GFC40015C1T) the Right Set?

Choose size 400 / 1/2 in ports when your line consumption outgrows a size 300 set; sizes 200, 300 and 600 cover smaller and larger steps. This unit uses the differential-pressure drain (blank position), which discharges condensate as pressure drop across the element builds - pick automatic (A) or manual (M) if you need timed or operator-controlled draining. The 40 um element is the standard grade; order the W suffix for 5 um. The C1 gauge code specifies a round external gauge on the MPa scale; psi and bar scales and the embedded square gauge are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015C1T) FAQ

There is no single rated flow figure to quote: AirTAC publishes G series performance as flow curves. Share your supply pressure, air demand and acceptable pressure drop, and we will confirm the datasheet curves and sizing for your application on request.

C1 specifies a round external pressure gauge on the MPa scale in place of the default embedded square gauge. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015C1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC40015C1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.