The AirTAC GFC400-15 Combination Unit (GFC40015C2T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-unit air preparation set: a filter-regulator that strips water and particulate from the air and holds downstream pressure, paired with a separate lubricator that meters oil mist into the line. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum inlet pressure is 1.0 MPa (145 psi), working temperature is -5 to 70 C non-freezing, and at the 400 size the filter-regulator and lubricator bowls are PC (polycarbonate).
This is a genuine AirTAC part. The GFC family spans sizes 200, 300, 400 and 600, with differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) filtration, square or round gauges in MPa, psi or bar scales, and G (BSPP) or NPT thread options to order. Flow figures are published as curves rather than a single rating - ask us to confirm sizing and the datasheet for your application. Order code GFC40015C2T has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GFC400-15 Combination Unit (GFC40015C2T) |
|---|---|
| Series | GFC400 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC400 | G-series two-unit set, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC400 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC300 |
| One size up | GFC600 |
| Three-unit equivalent | GC400-15 |
| Build order | Filter regulator first, lubricator last |
Conditioning air for impact wrenches and pneumatic nutrunners at an assembly station, where the lubricator extends tool life and the psi gauge matches US-standard plant gauges.
Supplying pneumatic clamps and swing cylinders on a stamping-press fixture, with the regulator holding a steady clamping pressure and the 40 um element guarding main valves.
Running leveller and dock-door cylinders at a loading dock, where the two-unit set keeps actuator air filtered, regulated and lubricated in one installation.
Match the size to the job: 200 through 600 step up in port and flow capacity, and the 400 size with NPT1/2 ports serves larger machine supply lines. Drain choice is real here: differential-pressure (as fitted) drains with flow and gives a 0.15-0.9 MPa (20-130 psi) setting range, automatic drains unattended, and manual widens the setting range to 0.05-0.9 MPa (7-130 psi). Filtration is the 40 um standard element; specify the W variant for 5 um where fine pilot valves need cleaner air. The C2 code selects the external round gauge in psi - MPa and bar scales are the C1 and C3 options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are catalogue options to order.
Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.
AirTAC publishes G-series flow as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure, port size and downstream demand and we will confirm the sizing and provide the datasheet on request.
The C2 code selects the external round gauge on a psi scale, convenient where US-unit gauges are the plant standard. Choose C1 for MPa or C3 for bar if your instrumentation differs. Everything else in this code - 400 size, NPT1/2 NPT ports, 40 um element, differential-pressure drain - stays the same across the gauge variants.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.