verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015C2T)

The AirTAC GFC400-15 Combination Unit (GFC40015C2T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$124.12 $131.62Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC400-15 Combination Unit (GFC40015C2T)

The AirTAC GFC series is a two-unit air preparation set: a filter-regulator that strips water and particulate from the air and holds downstream pressure, paired with a separate lubricator that meters oil mist into the line. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum inlet pressure is 1.0 MPa (145 psi), working temperature is -5 to 70 C non-freezing, and at the 400 size the filter-regulator and lubricator bowls are PC (polycarbonate).

This is a genuine AirTAC part. The GFC family spans sizes 200, 300, 400 and 600, with differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) filtration, square or round gauges in MPa, psi or bar scales, and G (BSPP) or NPT thread options to order. Flow figures are published as curves rather than a single rating - ask us to confirm sizing and the datasheet for your application. Order code GFC40015C2T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC400-15 Combination Unit (GFC40015C2T) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015C2T)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015C2T)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015C2T) Is Used

factory

Automotive assembly tools

Conditioning air for impact wrenches and pneumatic nutrunners at an assembly station, where the lubricator extends tool life and the psi gauge matches US-standard plant gauges.

precision_manufacturing

Press-shop clamping fixtures

Supplying pneumatic clamps and swing cylinders on a stamping-press fixture, with the regulator holding a steady clamping pressure and the 40 um element guarding main valves.

local_shipping

Trailer dock equipment

Running leveller and dock-door cylinders at a loading dock, where the two-unit set keeps actuator air filtered, regulated and lubricated in one installation.

Is the AirTAC GFC400-15 Combination Unit (GFC40015C2T) the Right Set?

Match the size to the job: 200 through 600 step up in port and flow capacity, and the 400 size with NPT1/2 ports serves larger machine supply lines. Drain choice is real here: differential-pressure (as fitted) drains with flow and gives a 0.15-0.9 MPa (20-130 psi) setting range, automatic drains unattended, and manual widens the setting range to 0.05-0.9 MPa (7-130 psi). Filtration is the 40 um standard element; specify the W variant for 5 um where fine pilot valves need cleaner air. The C2 code selects the external round gauge in psi - MPa and bar scales are the C1 and C3 options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are catalogue options to order.

Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015C2T) FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure, port size and downstream demand and we will confirm the sizing and provide the datasheet on request.

The C2 code selects the external round gauge on a psi scale, convenient where US-unit gauges are the plant standard. Choose C1 for MPa or C3 for bar if your instrumentation differs. Everything else in this code - 400 size, NPT1/2 NPT ports, 40 um element, differential-pressure drain - stays the same across the gauge variants.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015C2T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC40015C2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.