verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015MNT)

The AirTAC GFC400-15 Combination Unit (GFC40015MNT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$116.72 $124.22Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC400-15 Combination Unit (GFC40015MNT)

The AirTAC GFC40015MNT is a two-unit air-treatment set: a filter regulator and a separate lubricator in one 400-size package, so compressed air is filtered, regulated and lubricated in a single installation. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The regulator is the standard type and, with the manual-drain configuration, adjusts over 0.05-0.9 MPa (7-130 psi); maximum working pressure is 1.0 MPa (145 psi). No gauge is fitted in this code, so downstream pressure is read on your own instrumentation.

This is a genuine AirTAC part from the G series, which spans 200, 300, 400 and 600 sizes with optional G (BSPP) and NPT thread variants, automatic or differential-pressure drains, a 5 um (W) element option and gauge choices on regulator-equipped units. The 400-size bowls on the filter and lubricator are PC (polycarbonate). Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing figures on request.

AirTAC GFC400-15 Combination Unit (GFC40015MNT) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015MNT)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015MNT)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015MNT) Is Used

factory

Plant-air feed to an assembly hall

Fit the GFC40015MNT at the take-off from a factory compressed-air ring main to deliver clean, regulated and oil-misted air to the assembly hall's drop lines, with the manual drain blown down during shift checks.

settings_input_component

Pneumatic panel serving multiple actuators

Mount the set on the panel feeding a bank of cylinders and air-operated valves, so one 1/2 inch regulated supply points and lubricates every actuator downstream without individual treatment units.

conveyor_belt

Conveyor air-blast and clamp supply

Install the two-unit set ahead of a conveyor line's clamping cylinders and cleaning air blasts, combining 40 um filtration, set-line pressure and oil mist for the cylinders in one wall-mounted point.

Is the AirTAC GFC400-15 Combination Unit (GFC40015MNT) the Right Set?

The 400 size with NPT1/2 ports is the step to choose when your supply line is 1/2 inch and the 300/NPT3/8 size would sit near the top of its curve; if your demand is lighter, a 300-size set costs less and takes less panel space. Drain choice matters here: this code has a manual drain, which suits attended installations where an operator blows down the bowl, while automatic or differential-pressure drains suit unattended lines. The 40 um element is the standard grade for general plant air; pick the 5 um (W) version where finer pre-filtration is wanted. No gauge is included, so decide whether to add a gauge code at ordering. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015MNT) FAQ

AirTAC publishes flow for the 400-size G series as characteristic curves, not as a single rated number, so quoting one figure would be misleading. Tell us your line pressure and required consumption and we will confirm the sizing against the datasheet on request before you order.

M is the manual drain on the filter bowl and N means no gauge is fitted, so pressure is set on your own instrumentation. If you want a fitted gauge, AirTAC offers regulator-equipped G-series units with embedded square or external round gauges in MPa, psi or bar scales - ask us for the right code.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015MNT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC40015MNT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.