The AirTAC GFC400-15 Combination Unit (GFC40015NT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC40015NT is AirTAC's G-series two-unit air preparation set for 1/2 in NPT threaded lines. It pairs a filter-regulator with a lubricator, so filtration, pressure regulation and oil-mist lubrication of compressed air are handled by one assembly. This configuration uses the standard 40 um filter element and a differential-pressure drain on the filter bowl, and the trailing N means no pressure gauge is fitted.
This is a genuine AirTAC part in the 400 size of the G series, which also spans 200, 300 and 600 sizes with ports from 1/8 to 1 in. Options across the series include automatic or manual drains, a 5 um element (W code), a check valve (K code), gauge variants, and G (BSPP) or NPT threads. We confirm flow and datasheet figures on request.
| Model | AirTAC GFC400-15 Combination Unit (GFC40015NT) |
|---|---|
| Series | GFC400 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC400 | G-series two-unit set, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC400 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC300 |
| One size up | GFC600 |
| Three-unit equivalent | GC400-15 |
| Build order | Filter regulator first, lubricator last |
Conditions the air feeding the tool-changer, clamp and chuck circuits of a CNC machining center: particulate and water removed, pressure held steady, and a fine oil mist carried to the actuating valves.
Prepares the supply for the cylinders and grippers on a carton-sealing conveyor line, where clean, regulated and lubricated air keeps flap-fold and taping heads moving all shift.
Feeds impact wrenches and nutrunners at a bench or overhead-rail assembly station, delivering filtered air at the set pressure with lubrication for the tool motors.
Move up or down a size (200, 300, 400, 600) to match the port and air demand of your line; the 400 size shown here carries the 1/2 in NPT port. Choose the drain: differential-pressure (this model), automatic (A) for unattended condensate removal, or manual (M). The 40 um element suits general plant air; specify the W variant for 5 um filtration. Instead of the N no-gauge code you can order a gauge version with round or square gauges in MPa, psi or bar scales, and threads are available as three thread types (NPT on this code). Flow for this series is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.
AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm the flow from the datasheet on request before you order.
The trailing N in the code means no gauge is fitted. Gauge variants of the GFC400 are available with round or square gauges in MPa, psi or bar scales; ask us to quote the gauge version if you want a visible pressure reading at the regulator.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.