Genuine AirTAC precision filter regulator, order code GPFR300N08SND from the GPFR300-08 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
Ordering GPFR300N08SND selects three things at once: the N nylon bowl, the S standard pressure type, and the D element grade - the 0.01 um, 99.9% efficient element that removes far finer particles and oil mist than the M grade. The N gauge option means this unit ships without a pressure gauge, so set points must be read from instrumentation fitted elsewhere in the circuit.
The D element trades flow for cleanliness: rated flow is 180 L/min (inlet 0.7 MPa, outlet 0.5 MPa) against 330 L/min for the M version, so size downstream demand accordingly. Pressure regulation still spans 0.15 - 0.9 MPa (20 - 130 psi) with 1.0 MPa (145 psi) maximum operating pressure and 1.5 MPa (215 psi) proof pressure. The 60 cc nylon bowl drains via the differential plus manual mechanism, the bracket is included, and ports are 1/4 inch PT.
| Order code | GPFR300N08SND |
|---|---|
| Product | Precision Filter Regulator |
| Bowl · drain | Nylon bowl (N) · Differential + manual drain |
| Type · gauge | Standard (S) · No gauge (N) |
| Configuration | 0.01 µm element (D) · With bracket · PT thread |
| Port | 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 0.3 µm (M) / 0.01 µm (D), 99.9% efficiency |
| Drain bowl capacity | 60 cc |
| Weight | 500 g |
| Fluid | Air |
| Regulating range | 0.15 – 0.9 MPa (20 – 130 psi) |
| Low-pressure (L) version | up to 0.4 MPa (58 psi) |
| Maximum pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -5 to +70 °C (no freezing) |
| Rated flow | M: 330 L/min · D: 180 L/min (inlet 0.7 MPa, outlet 0.5 MPa) |
Source: AirTAC Products Catalog 2026A (p.246, PDF01-P0248), GPFR ordering code and specifications.
Choose GPFR300N08SND over GPFR300N08SNM when oil-mist carryover or sub-micron contamination is the problem and 180 L/min of rated flow is enough; step back to the M code for double the flow at 0.3 um. Both codes carry N for no gauge, unlike the gauge-fitted sibling, and both use the standard differential plus manual drain - add A to the code if an automatic drain is preferred. C in the bowl position would swap nylon for metal.
AirtacDistr lists every GPFR300-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gpfr300-08-precision-filter-regulator
Protect sensitive pneumatic components with 0.01 um air; the D element captures fine oil mist at 99.9% efficiency where the 0.3 um M grade would let sub-micron particles through.
Feed instruments and test rigs from a 1/4 inch PT supply regulated between 0.15 and 0.9 MPa (20 - 130 psi); with no gauge fitted, integrate reading into your own panel instrumentation.
Supply spray, jet or marking heads that clog from oil aerosol; the manual drain empties the 60 cc nylon bowl on schedule since this code uses differential plus manual, not automatic, drainage.
Port 1/4 inch with PT thread standard; element D at 0.01 um, 99.9% efficiency; rated flow 180 L/min (inlet 0.7 MPa, outlet 0.5 MPa); regulating range 0.15 - 0.9 MPa (20 - 130 psi); maximum pressure 1.0 MPa (145 psi); proof pressure 1.5 MPa (215 psi); bowl nylon, 60 cc, differential plus manual drain; no gauge fitted; bracket included; weight 500 g.
The 0.01 um D element restricts rated flow to 180 L/min, roughly half the 330 L/min of the 0.3 um M element under the same 0.7 MPa inlet and 0.5 MPa outlet conditions. If your consumption approaches the D-element limit, either move to the M code or confirm the acceptable flow margin from the datasheet before ordering.