The AirTAC GFR300C08LF1WT AirTAC Filter Regulator NPT1/4 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300C08LF1WT is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is the 300 size with a 1/4 in NPT port, the 5 um filter element (code W, against the 40 um standard), a differential-pressure drain, the low-pressure regulator type, a fitted square gauge with MPa scale, and the mounting bracket included. No reverse (check) valve is fitted.
It is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, and with choices of thread (PT standard; G and NPT are order options), drain type, filter grade, gauge and scale. Because flow is published as curves rather than a single rating, we confirm flow and other datasheet figures for your application on request.
| Model | GFR300C08LF1WT AirTAC Filter Regulator NPT1/4 Low-Pressure |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C0 (two-unit set) |
Clean, regulated low-pressure air to clamping cylinders on a CNC fixture, with the 5 um element protecting valve and cylinder seals from finer particulate and the differential-pressure drain clearing collected water.
A bench test rig that needs clean air held at a low, stable pressure; the square MPa gauge gives a direct local reading and the differential-pressure drain removes condensate without manual attention.
Water and particulate removal plus pressure regulation in one 1/4 in NPT body feeding carton-sealing and wrapping machines, saving panel space where a separate filter and regulator would not fit.
The real choices in this family are the size and port step (200/300/400/600, 1/8 to 1 in) matched to the air demand of the line; the drain type (differential-pressure as here, automatic, or manual); the filter grade (40 um standard, 5 um with code W); the gauge and its scale (MPa, psi or bar); the thread (PT standard, G or NPT to order); and the bracket. This unit is the low-pressure regulator type; its adjustment range is not published as a single figure, so ask us to confirm it. Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 as curves, not as a single rated figure, so we do not quote a number here. Tell us your operating pressure and air demand and we will confirm the sizing from the datasheet on request.
The standard GFR filter grade is 40 um; the W code on this model specifies the optional 5 um grade, which suits downstream components sensitive to finer particulate. If your application does not need the finer grade, ask us about the standard 40 um configuration.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.