The AirTAC GFR300C08LJNWTK AirTAC Filter Regulator NPT1/4 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C08LJNWTK is an AirTAC GFR300 filter regulator: water and particulate filtration plus pressure regulation combined in a single body, with a 1/4 in NPT port. This configuration carries a 5 um filter element (the finer of the two published grades), a differential-pressure drain and a metal bowl. The regulator is the low-pressure type, a reverse/check valve is fitted, and no gauge or mounting bracket is supplied.
It is a genuine AirTAC part. The G-series filter-regulator line spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, and gauge and thread options. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm figures from the datasheet for your application.
| Model | GFR300C08LJNWTK AirTAC Filter Regulator NPT1/4 5 um |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C0 (two-unit set) |
Feeding spray guns on a wood-finishing line: the 5 um element keeps water and particulate out of the air reaching the guns, while the regulator holds a steady supply pressure to the finishing station.
Supplying pneumatic clamps around a robotic weld cell. The low-pressure regulator type suits circuits that hold workpieces at reduced pressure, and this configuration includes a reverse/check valve.
Air preparation for diverters, stoppers and small cylinders along a packaging conveyor: one body does the filtering and the regulating, with a differential-pressure drain.
Choose the size step (200/300/400/600) against the flow your line needs - the larger the size, the larger the port and flow path; this unit sits at size 300 with a 1/4 in NPT port. Drain type is a real choice: differential-pressure (fitted here), automatic, or manual. Filter grade is 40 um standard or 5 um with the W code - this model carries the 5 um element. Gauge and scale, PT vs G/NPT thread, and bracket are also selectable; this configuration has no gauge and no bracket, and adds a reverse/check valve.
Flow for this family is published as curves, not a single rated figure, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow figures from the datasheet on request.
The N in GFR300C08LJNWTK specifies the unit without a gauge. Gauges - embedded square or external round, with MPa, psi or bar scales - are available on other GFR300 configurations; ask us if you need a gauged variant.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.