verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR300C08MF2T AirTAC Filter Regulator NPT1/4

The AirTAC GFR300C08MF2T AirTAC Filter Regulator NPT1/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$47.89 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR300C08MF2T AirTAC Filter Regulator NPT1/4

The AirTAC GFR300C08MF2T is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady in a single body. This size 300 unit is threaded NPT1/4, carries a manual drain on its polycarbonate bowl, uses the standard 40 um filter element, and has a standard regulator with a 0.05-0.9 MPa (7-130 psi) setting range. The embedded square gauge reads in psi, and a mounting bracket is included.

This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, PT, G or NPT threads, differential-pressure, automatic or manual drains, 40 um or 5 um (code W) filtration, and MPa, psi or bar gauge scales. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application.

GFR300C08MF2T AirTAC Filter Regulator NPT1/4 Technical Specifications

ModelGFR300C08MF2T AirTAC Filter Regulator NPT1/4
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR300C08MF2T AirTAC Filter Regulator NPT1/4

GFR300G-series filter regulator, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C0 (two-unit set)

Where the GFR300C08MF2T AirTAC Filter Regulator NPT1/4 Is Used

precision_manufacturing

Pneumatic press supply

Feeding a bench-mounted pneumatic press on an assembly line: the 40 um element strips water and swarf from the shop air before it reaches the valve, and the regulator holds a steady set pressure so cylinder force stays repeatable from stroke to stroke.

conveyor_belt

Packaging line actuation

Supplying air to carton-sealers and diverters on a packaging conveyor: clean, regulated air keeps the small cylinders and air jets on the line behaving consistently through a shift, and the manual drain lets an operator clear condensate at the start of each day.

build

Robotic pick-and-place cell

Conditioning the air feed to a robot gripper circuit: the filter stage protects the gripper valve from moisture and particles, the regulator pins supply pressure for gentle, repeatable part handling, and the psi gauge gives the technician a visible setpoint at the cell.

Is the GFR300C08MF2T AirTAC Filter Regulator NPT1/4 the Right Unit?

Size and port set the air capacity: the GFR300 steps up from the compact 200 series and takes NPT1/4 piping here, so match the port step to the line feeding your downstream equipment. This unit is ordered with a manual drain, which you open by hand to release collected water; choose the automatic (A) or differential-pressure (blank) drain variant of the same size if the unit sits where manual draining is impractical. The 40 um element is the standard grade - specify W for 5 um where finer filtration is needed. The square gauge reads in psi, with MPa and bar scales as alternatives and an external round gauge optional. PT is the standard thread; G and NPT are order options, as NPT is here. A bracket is included.

Flow for the GFR series is published as curves, not a single rated figure, so send us your flow requirement and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR300C08MF2T AirTAC Filter Regulator NPT1/4 FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure and air demand and we will confirm the sizing from the datasheet on request.

The M in the code means the bowl drains by hand: open it periodically to release collected water. If the unit will be mounted where it cannot easily be reached, order the automatic (A) or differential-pressure (blank) drain variant of the same size instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR300C08MF2T AirTAC Filter Regulator NPT1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C08MF2T and will confirm price, stock and lead time — usually within 7-8 hours.