The AirTAC GFR300C08MLJNWT AirTAC Filter Regulator NPT1/4 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300C08MLJNWT is a filter regulator: it removes water and particulate from compressed air and reduces pressure to the working level in a single body. This configuration is the low-pressure regulator type, with 1/4 in NPT ports, a 5 um filter element (the finer of the two published grades), a manual drain on the metal bowl, and no gauge, bracket or reverse/check valve fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in and PT, G or NPT threads. The exact regulation range for this low-pressure type is not published; we confirm it, together with the flow curves and full datasheet, on request.
| Model | GFR300C08MLJNWT AirTAC Filter Regulator NPT1/4 5 um |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C0 (two-unit set) |
Feeds hold-down clamps and positioning cylinders that run at reduced pressure, with the 5 um element keeping fine dust and debris out of valve seats and the manual drain emptied as part of the shift-start routine.
Supplies filtered, regulated air to bench-top test rigs and pilot lines that operate below standard shop pressure, where the low-pressure regulator type matches the working band and the manual drain suits intermittent running.
Runs the air cylinders that kick rejected packs off a conveyor, combining water and particle removal with downstream pressure control in one compact body instead of two separate components.
Size and port step up together: this is size 300 with 1/4 in NPT ports, and larger sizes carry larger ports and higher flow capacity. Because AirTAC publishes flow as curves rather than a single rating, ask us to confirm sizing against your application before ordering. The other real choices in this family are drain type (manual here; automatic or differential-pressure available), filter grade (5 um here; 40 um is the standard grade), gauge and scale (none fitted on this unit), thread (PT is the standard; G and NPT are order options) and mounting bracket (not fitted here).
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this series as curves rather than a single rated figure, so no one number is quoted here. Send us your line pressure, required working pressure and downstream air demand, and we will confirm the flow from the datasheet before you order.
The N in the model code means no gauge is fitted. GFR units with a regulator can carry an embedded square gauge or an optional external round gauge with an MPa, psi or bar scale, so ask us if you want a gauged variant instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.